Technical data
TRBMIM Events and Alarms
Event and Alarm Messages TRBMIM
4-4 Management Module Guide
CsEvFormat/Event0042011a
{d Ò%w- %d %m-, %Y - %TÓ} - TEMPERATURE
HOT - Device {m} of Type {t} reported that the
Module {I 1} Temperature is Hot. - (event [{e}])
CsPCause/Prob0042011a
TEMPERATURE HOT
SYMPTOMS:
A Module may be defective or a fan has failed in
the Chassis. A serious heat condition is present
and should be addressed immediately.
RECOMMENDED ACTIONS:
1) Verify that Module is not defective.
2) Check for fans failures in the Chassis and
repair as needed.
CsEvFormat/Event0042011b
{d Ò%w- %d %m-, %Y - %TÓ} - VOLTAGE LOW -
Device {m} of Type {t} reported that the Slot {I 1}
Power Supply Voltage is Low. - (event [{e}])
CsPCause/Prob0042011b
VOLTAGE LOW
SYMPTOMS:
The internal voltage of the Power Supply Module
is Low.
PROBABLE CAUSES:
1) The Power Supply unit is defective.
2) An AC Power Failure has occurred in the Power
Supply.
RECOMMENDED ACTIONS:
1) Check the Power Supply unit on device.
2) Check Power source to device.
CsEvFormat/Event0042011c
{d Ò%w- %d %m-, %Y - %TÓ} - TEMPERATURE
NORMAL - Device {m} of Type {t} reported that
the Module {I 1} Temperature is Normal. - (event
[{e}])
No probable cause message.
CsEvFormat/Event0042011d
{d Ò%w- %d %m-, %Y - %TÓ} - VOLTAGE
NORMAL - Device {m} of Type {t} reported that
the Slot {I 1} Power Supply Voltage is Normal. -
(event [{e}])
No probable cause message.
Table 4-1. TRBMIM Events and Alarms (Sheet 3 of 23)
System Event Log Message
Source and Text
Alarm View Probable Cause Message
Source and Text