Technical data
9031251 E6 Event and Alarm Messages
4-3
TRBMIM Events and Alarms
CsEvFormat/Event00010309
{d Ò%w- %d %m-, %Y - %TÓ} A(n) {t} device, named
{m}, has detected a communication Link Up.
(event [{e}])
CsEvFormat/Event00010309
{d Ò%w- %d %m-, %Y - %TÓ} A(n) {t} device, named
{m}, has detected a communication Link Up.
(event [{e}])
CsEvFormat/Event0001030a
{d Ò%w- %d %m-, %Y - %TÓ} A(n) {t} device, named
{m}, has detected an Authentication Failure.
(event [{e}])
CsPCause/Prob0001030a
Authorization failure. Other user is trying to
connect to device with an invalid community
string.
CsEvFormat/Event0001030b
{d Ò%w- %d %m-, %Y - %TÓ} A(n) {t} device, named
{m}, has detected an EGP Neighbor Loss. EGP
Neighbor IP address is {O 1}. (event [{e}])
CsPCause/Prob0001030b
Lost contact with EGP neighbor.
CsEvFormat/Event00420107
{d Ò%w- %d %m-, %Y - %TÓ} - MODULE
REMOVAL - Device {m} of Type {t} reported that
Module {I 1} has been Removed. - (event [{e}])
CsPCause/Prob00420107
MODULE REMOVAL
SYMPTOMS:
A Module within this Chassis has been Removed
or has Failed.
CsEvFormat/Event00420108
{d Ò%w- %d %m-, %Y - %TÓ} - MODULE
INSERTION - Device {m} of Type {t} reported that
a Module has been Inserted into Slot {I 1}. -
(event [{e}])
CsPCause/Prob00420108
MODULE INSERTION
SYMPTOMS:
A Module has been Inserted into this Chassis.
CsEvFormat/Event00420119
{d Ò%w- %d %m-, %Y - %TÓ} - TEMPERATURE
WARM - Device {m} of Type {t} reported that the
Module {I 1} Temperature is Warm. - (event [{e}])
CsPCause/Prob00420119
TEMPERATURE WARM
SYMPTOMS:
The Module may be defective or a fan has failed in
the Chassis.
RECOMMENDED ACTIONS:
1) Verify that Module is not defective.
2) Check for fans failures in the Chassis and
repair as needed.
Table 4-1. TRBMIM Events and Alarms (Sheet 2 of 23)
System Event Log Message
Source and Text
Alarm View Probable Cause Message
Source and Text