Technical data
Token Ring Station Table Views
Token Ring Station Alarm Thresholds View
ConÞguration & Station Table Views TRBMIM
3-36 Management Module Guide
the Token ring Station Table view, the Token Ring Station Isolating Errors
view, or the Token Ring Station Non-Isolating Errors view (refer to Token Ring
Station Table View Details, starting on page 3-29).
Token Ring Station Alarm Thresholds View Details
In addition to the general conÞguration information common to most generic
views, enclosed within the status border in the top part of the view, the Token
Ring Isolating Errors Table view displays the same Ring Name, Ring Number,
Ring Speed, Ring Status, and Active Monitor information as presented in the
Token Ring Station Table view (refer to descriptions of these Þelds on
page 3-29).
The blocked-off Station Alarm Thresholds Table area in the lower half of
the screen also uses the same tabular setup as the previously described Token
Ring Station Table view, with all but one of the columns having the same
button-readout headings, but the meanings are slightly different in this case,
as described below. In addition, this table setup includes the same Update,
Totals/Deltas, MAC/Canonical, Sort Up/Sort Down/Un-Sort, and Set/Clear
Filter control buttons across the top of the table, and the same Station Detail,
Station Alarms, and Remove Station selection buttons below the table entries.
For information on these Þelds and controls, refer to Token Ring Station Table
View Details, starting on page 3-29.
What is different about the Station Alarm Thresholds Table is that the data
columns identify the threshold settings for the different alarm conditions for
each station listed in the table. As with the other tables, each such column is
identiÞed by the readout of a selection button utilized as the column heading.
As with the Station Address and Station Name column buttons, which are the
same as on the Station Table, clicking on any of these buttons selects that
column as the column of interest for any subsequent activation of the sort-
function and Þlter function buttons. The added columns are as follows:
The current alarm threshold setting for line errors to be detected on the ring
with respect to the station to which the information in the line entry pertains.
(The resulting number of detections will appear in the Line column of the
Station Isolating Errors Table.)
The current alarm threshold setting for burst errors with respect to the
station to which the information in the line entry pertains. (The resulting
number of detections will appear in the Burst column of the Station Isolating
Errors Table.)
Line
Burst