Technical data

TRBMIM Events and Alarms
Event and Alarm Messages TRBMIM
4-22 Management Module Guide
CsEvFormat/Event00420235
{d Ò%w- %d %m-, %Y - %TÓ} - RING LOST
FRAMES THRESHOLD EXCEEDED - Device
{m} of Type {t} reported that the Ring Lost
Frames Threshold Value of {I 2} has been
Exceeded within the Timebase Value of {I 3} for
Ring {I 1}. - (event [{e}])
CsPCause/Prob00420235
RING LOST FRAMES THRESHOLD
EXCEEDED
SYMPTOMS:
The Ring Lost Frames Threshold Value has been
Exceeded.
PROBABLE CAUSE:
The Ring Lost Frame Error occurs when a Station
is transmitting and its timer for return expires.
The Lost Frame count keeps track of how many
frames transmitted by a Station fail to return. If a
frame becomes lost the Active Monitor will issue a
new Token.
CsEvFormat/Event00420236
{d Ò%w- %d %m-, %Y - %TÓ} - RING FRAME
COUNT THRESHOLD EXCEEDED - Device {m}
of Type {t} reported that the Ring Frame Count
Threshold Value of {I 2} has been Exceeded within
the Timebase Value of {I 3} for Ring {I 1}. - (event
[{e}])
CsPCause/Prob00420236
RING FRAME COUNT THRESHOLD
EXCEEDED
SYMPTOMS:
The Ring Frame Count Threshold Value has been
Exceeded.
CsEvFormat/Event00420237
{d Ò%w- %d %m-, %Y - %TÓ} - STATION LINE
ERRORS THRESHOLD EXCEEDED - Device
{m} of Type {t} reported that Station {X 4} has
Exceeded the Line Errors Threshold Value of {I 2}
within the Timebase Value of {I 3} for Ring {I 1}. -
(event [{e}])
CsPCause/Prob00420237
LINE ERRORS THRESHOLD EXCEEDED
SYMPTOMS:
The Line Errors Threshold Value has been
Exceeded.
CsEvFormat/Event00420238
{d Ò%w- %d %m-, %Y - %TÓ} - STATION
INTERNAL ERRORS THRESHOLD
EXCEEDED - Device {m} of Type {t} reported that
Station {X 4} has Exceeded the Internal Errors
Threshold Value of {I 2} within the Timebase
Value of {I 3} for Ring {I 1}. - (event [{e}])
CsPCause/Prob00420238
LOST INTERNAL ERRORS THRESHOLD
EXCEEDED
SYMPTOMS:
The Lost Internal Errors Threshold Value has
been Exceeded.
CsEvFormat/Event00420239
{d Ò%w- %d %m-, %Y - %TÓ} - STATION BURST
ERRORS THRESHOLD EXCEEDED - Device
{m} of Type {t} reported that Station {X 4} has
Exceeded the Burst Errors Threshold Value of {I
2} within the Timebase Value of {I 3} for Ring {I
1}. - (event [{e}])
CsPCause/Prob00420239
LOST BURST ERRORS THRESHOLD
EXCEEDED
SYMPTOMS:
The Lost Burst Errors Threshold Value has been
Exceeded.
Table 4-1. TRBMIM Events and Alarms (Sheet 21 of 23)
System Event Log Message
Source and Text
Alarm View Probable Cause Message
Source and Text