Technical data
9031251 E6 Event and Alarm Messages
4-19
TRBMIM Events and Alarms
CsEvFormat/Event0042022c
{d Ò%w- %d %m-, %Y - %TÓ} - PORT REMOVED
DURING FAULT RECOVERY - Device {m} of
Type {t} reported that Board {I 1}, Port Group {I
2}, Port {I 3} was Removed from the Ring during a
Fault Recovery Condition. - (event [{e}])
CsPCause/Prob0042022c
PORT REMOVED DURING FAULT RECOVERY
SYMPTOMS:
A Port was Removed from the Ring during a Fault
Recovery Condition.
PROBABLE CAUSES:
1) Bad cable connected to Removed Port.
2) Device connection is bad at other end of the
cable.
RECOMMENDED ACTIONS:
1) Check cable connected to Removed Port.
2) Check Device connection at other end of the
cable.
3) After problem is resolved, Enable the Removed
Port.
CsEvFormat/Event0042022e
{d Ò%w- %d %m-, %Y - %TÓ} - BOARD BYPASSED
DURING FAULT RECOVERY - Device {m} of
Type {t} reported that Board {I 1} was Bypassed
during a Fault Recovery Condition. - (event [{e}])
CsPCause/Prob0042022e
BOARD BYPASSED DURING FAULT
RECOVERY
SYMPTOMS:
A Module was Bypassed during a Fault Recovery
Condition.
PROBABLE CAUSES:
1) This Module is conÞgured with a different Ring
Speed than the Hub.
RECOMMENDED ACTIONS:
1) Pull out the Bypassed Module from the Hub.
2) Re-conÞgure this ModuleÕs Ring Speed to match
that of the Hub.
3) Physically insert the Module back into the Hub.
4) Set this ModuleÕs Bypass State to Inserted.
Table 4-1. TRBMIM Events and Alarms (Sheet 18 of 23)
System Event Log Message
Source and Text
Alarm View Probable Cause Message
Source and Text