Installation guide

Chapter 4: Troubleshooting, Switches, and LED Indications
4-4 SSR-600 Installation Guide
4.2 SWITCHES
The SSR-600 has two switches on the main motherboard, a thermal
switch and a switch bank.
Thermal Switch
The thermal switch will close if the temperature inside the device exceeds
65°C when the SSR-600 is operating. The thermal switch then notifies the
processor that the temperature in the SSR-600 exceeded 65°C. This
information can be used to send a trap and/or log a message.
Switch Bank
The four-position switch bank has the functions shown in Table 4-4. The
SSR-600 must be reset or powered down for the firmware to recognize the
settings of the switches, and then implement any changes.
The switch is used for the following functions:
Force download is used when the user wants to force the SSR-600 to
download a new image at bootup.
Restore Defaults is used to return the SSR-600 to the factory
configuration.
Table 4-4 Four Position Switch Bank Functions
Switch Function
1 Force download
2 Restore defaults
3 Currently unused
4 Currently unused