Specifications

Device View The SPECTRUM Model
Device Management Page 36 SmartSwitch 9000/9500 Series
Power Subsystem
Total - displays the maximum power that
could be supplied by the chassis power
supply.
Used - displays the total power currently
being supplied by the chassis power supply.
Avail - displays the available power from the
chassis power supply.
Status - displays the status and type of power
for the chassis: AC, DC, or Battery.
- Green - power normal.
- Yellow - over current, over voltage, or
under voltage.
Redundancy - displays the source of the
power for the chassis.
- Redundant - indicates that power from the
secondary power source is being used for
the chassis.
- NON-Redundant - indicates that power
from the primary power source is being
used for the chassis.
Main Pwr Bus - displays the voltage of the
chassis’s main power bus. The value can
range between 40 and 60 volts DC.
- Green - power normal.
- Yellow - over current, over voltage, or
under voltage.
Diag Pwr Bus - field does not function at this
time. A future version of firmware will include
this functionality.
INB Term - displays the voltage of the
termination power bus. The termination
power bus provides power to the INB
termination cards within the chassis.
- Green - power normal.
- Yellow - over current, over voltage, under
voltage, or over power.
UPS/Battery
Status - displays the UPS’s operational
status. Below are a list of colors and
conditions associated with this field.
- Red - overload, low battery, or replace
battery.
- Blue - no UPS.
- Green - on line.
- Yellow - calibration running.
Run Time - displays the estimated remaining
run time in minutes. You can query the UPS
when operating on-line, bypass, or on-battery