Specifications
MicroMMAC-T Events and Alarms
Event and Alarm Messages MicroMMAC-T
4-22 Management Module Guide
Event00420233
{d "%w- %d %m-, %Y - %T"} - RING
TOKEN ERRORS THRESHOLD
EXCEEDED - Device {m} of Type {t}
reported that the Ring Token Errors
Threshold Value of {I 2} has been
Exceeded within the Timebase
Value of {I 3} for Ring {I 1}. - (event
[{e}])
Prob00420233
RING TOKEN ERRORS THRESHOLD
EXCEEDED
SYMPTOMS:
The Ring Token Errors Threshold Value has
been Exceeded.
PROBABLE CAUSE:
The Active Monitor has recognized an error
condition that requires a Token to be
transmitted. This occurs when the timer for
a valid transmission expires (10ms).
Event00420234
{d "%w- %d %m-, %Y - %T"} - RING
CLAIM TOKEN THRESHOLD
EXCEEDED - Device {m} of Type {t}
reported that the Ring Claim Token
Threshold Value of {I 2} has been
Exceeded within the Timebase
Value of {I 3} for Ring {I 1}. - (event
[{e}])
Prob00420234
RING CLAIM TOKEN THRESHOLD
EXCEEDED
SYMPTOMS:
The Ring Claim Token Threshold Value has
been Exceeded.
PROBABLE CAUSES:
When a Station in Standby Monitor state
has determined that there is no Active
Monitor operating on the Ring. If the Station
claims the Token, it becomes the new Active
Monitor for the Ring.
Table 4-1. MicroMMAC-T Events and Alarms (Continued)
Message in the Event Log
Alarm View Probable Caulse
Message