Specifications

MicroMMAC-T Events and Alarms
Event and Alarm Messages MicroMMAC-T
4-20 Management Module Guide
Event0042022e
{d "%w- %d %m-, %Y - %T"} -
BOARD BYPASSED DURING
FAULT RECOVERY - Device {m} of
Type {t} reported that Board {I 1}
was Bypassed during a Fault
Recovery Condition. - (event [{e}])
Prob0042022e
BOARD BYPASSED DURING FAULT
RECOVERY
SYMPTOMS:
A Module was Bypassed during a Fault
Recovery Condition.
PROBABLE CAUSES:
1) This Module is configured with a different
Ring Speed than the Hub.
RECOMMENDED ACTIONS:
1) Pull out the Bypassed Module from the
Hub.
2) Re-configure this Module's Ring Speed to
match that of the Hub.
3) Physically insert the Module back into the
Hub.
4) Set this Module's Bypass State to
Inserted.
Event0042022f
{d "%w- %d %m-, %Y - %T"} - PORT
VIOLATION - Device {m} of Type {t}
reported that Board {I 1}, Port
Group {I 2}, Port {I 3} has detected a
Link while the Port's Management
State was Disabled. - (event [{e}])
No probable cause message
Event00420230
{d "%w- %d %m-, %Y - %T"} - PORT
VIOLATION CLEARED - Device
{m} of Type {t} reported that Board
{I 1}, Port Group{I 2} in Port {I 3}
has detected an Unlink while the
Port's Management State was
Disabled. - (event [{e}])
No probable cause message
Table 4-1. MicroMMAC-T Events and Alarms (Continued)
Message in the Event Log
Alarm View Probable Caulse