Specifications
9031755 E6 Event and Alarm Messages
4-7
MicroMMAC-T Events and Alarms
Event00420205
{d "%w- %d %m-, %Y - %T"} - RING
PORT FAULTED - Device {m} of
Type {t} reported
that Ring Port {I 2} in Module {I 1}
has entered the Wrapped State
while its Management State was
Enabled. - (event [{e}])
Prob00420205
RING PORT FAULTED
SYMPTOMS:
A Ring Port has entered the Wrapped State
while its Management State was Enabled.
PROBABLE CAUSES:
1) Bad cable connected to affected Port.
2) Device is down at other end of the cable.
3) Device connection is bad at other end of
the cable.
RECOMMENDED ACTIONS:
1) Check cable connected to affected Port.
2) Power up Device at other end of the cable.
3) Check Device connection at other end of
the cable.
Event00420206
{d "%w- %d %m-, %Y - %T"} - RING
PORT FAULT CLEARED - Device
{m} of Type {t} reported that Ring
Port {I 2} in Module {I 1} has left the
Wrapped State. - (event [{e}])
No probable cause message
Table 4-1. MicroMMAC-T Events and Alarms (Continued)
Message in the Event Log
Alarm View Probable Caulse
Message