Specifications
9031755 E6 Event and Alarm Messages
4-5
MicroMMAC-T Events and Alarms
Event00420125
{d "%w- %d %m-, %Y - %T"} -
VOLTAGE LOW - Device {m} of
Type {t} reported that thesystem
power supply voltage is low. - (event
[{e}])
Prob00420125
VOLTAGE LOW
SYMPTOMS:
The internal voltage of the System Power
Supply is Low.
PROBABLE CAUSES:
1) The Power Supply unit is defective.
2) An AC Power Failure has occurred in the
System Power Supply.
RECOMMENDED ACTIONS:
1) Check the System Power Supply unit on
the device.
2) Check Power source to device.
Event00420126
{d "%w- %d %m-, %Y - %T"} -
VOLTAGE NORMAL - Device {m} of
Type {t} reported that the System
Power Supply Voltage has returned
to Normal. - (event [{e}])
No probable cause message
Event00420136
{d "%w- %d %m-, %Y - %T"} -
MODULE INSERTION - Device {m}
of Type {t} reported that a Module
has been Inserted into Slot {I 1}. -
(event [{e}])
Prob00420136
MODULE INSERTION
SYMPTOMS:
A Module has been Inserted into this
Chassis.
Event00420201
{d "%w- %d %m-, %Y - %T"} - PORT
INSERTED - Device {m} of Type {t}
reported that a Station has been
Inserted into Port {I 2} in Module {I
1}.- (event [{e}])
No probable cause message.
Table 4-1. MicroMMAC-T Events and Alarms (Continued)
Message in the Event Log
Alarm View Probable Caulse
Message