Specifications

9031755 E6 Event and Alarm Messages
4-3
MicroMMAC-T Events and Alarms
Event0042011a
{d "%w- %d %m-, %Y - %T"} -
TEMPERATURE HOT - Device {m}
of Type {t} reported that the Module
{I 1} Temperature is Hot. - (event
[{e}])
Prob0042011a
TEMPERATURE HOT
SYMPTOMS:
A Module may be defective or a fan has
failed in the Chassis. A serious heat
condition is present and should be addressed
immediately.
RECOMMENDED ACTIONS:
1) Verify that Module is not defective.
2) Check for fans failures in the Chassis and
repair as needed.
Event0042011b
{d "%w- %d %m-, %Y - %T"} -
VOLTAGE LOW - Device {m} of
Type {t} reported that the Slot {I 1}
Power Supply Voltage is Low. -
(event [{e}])
Prob0042011b
VOLTAGE LOW
SYMPTOMS:
The internal voltage of the Power Supply
Module is Low.
PROBABLE CAUSES:
1) The Power Supply unit is defective.
2) An AC Power Failure has occurred in the
Power Supply.
RECOMMENDED ACTIONS:
1) Check the Power Supply unit on device.
2) Check Power source to device.
Event0042011c
{d "%w- %d %m-, %Y - %T"} -
TEMPERATURE NORMAL -
Device {m} of Type {t} reported that
the Module {I 1} Temperature is
Normal. - (event [{e}])
No probable cause message
Table 4-1. MicroMMAC-T Events and Alarms (Continued)
Message in the Event Log
Alarm View Probable Caulse
Message