Specifications
MicroMMAC-T Events and Alarms
Event and Alarm Messages MicroMMAC-T
4-2 Management Module Guide
Table 4-1. MicroMMAC-T Events and Alarms
Message in the Event Log
Alarm View Probable Caulse
Message
Event000d0001
{d "%w- %d %m-, %Y - %T"} Bridge
{m} of type {t} has reported a root
change (event [{e}]).
Prob000d0001
This bridge has become the new root of the
Spanning Tree.
Event000d0002
{d "%w- %d %m-, %Y - %T"} Bridge
{m} of type {t} has reported a
network
topology change (event [{e}]).
Prob000d0002
A port has transitioned from the Learning
state to the Forwarding state, or from the
Forwarding state to the Blocking state.
Event00420107
{d "%w- %d %m-, %Y - %T"} -
MODULE REMOVAL - Device {m}
of Type {t} reported that Module {I
1} has been Removed. - (event [{e}])
Prob00420107
MODULE REMOVAL
SYMPTOMS:
A Module within this Chassis has been
Removed or has Failed.
Event00420108
{d "%w- %d %m-, %Y - %T"} -
MODULE INSERTION - Device {m}
of Type {t} reported that a Module
has been Inserted into Slot {I 1}. -
(event [{e}])
No probable cause message
Event00420119
{d "%w- %d %m-, %Y - %T"} -
TEMPERATURE WARM - Device
{m} of Type {t} reported that the
Module {I 1} Temperature is Warm.
- (event [{e}])
Prob00420119
TEMPERATURE WARM
SYMPTOMS:
The Module may be defective or a fan has
failed in the Chassis.
RECOMMENDED ACTIONS:
1) Verify that Module is not defective.
2) Check for fans failures in the Chassis and
repair as needed.