Specifications

Table Of Contents
ST1kAd10App AD 10 Status Administration
SPECTRUM Enterprise Manager 79 of 194 Ascom TimePlex ST-1000
responseTimeout
,
resetTimeout
,
infoIncorrect
, and
ad10LinkDown
.
FileSize
The total number of bytes to be softloaded. If no
softloading is in progress, the value is
0
.
Transferred
The number of bytes that have been transferred.
If no softloading is in progress, the value is
0
.
StartTime
Indicates when the softload of this AD 10 unit
was started. The value is the number of seconds
since midnight on January 1, 1970. A value of
0
means that the softload start time is not
applicable.
CompletionTime
Indicates when the softload of this AD 10 unit
was completed. The value is the number of
seconds since midnight on January 1, 1970. A
value of
0
means that the softload start time is
not applicable.
AD 10 Data/Voice Port Status
This area in the AD 10 Status Administration
view contains two buttons that access the
information described below.
This button provides access to the following
fields.
Addr
The AD 10 port address.
Mode
A read-write field that can be set to
offline
,
online
,
disableDiagnostics
,
bertTowardSubscriber
,
bertTowardNetwork
,
loopSubscriber
, or
loopNetwork
.
IntfType
A read-only field that displays the interface type.
The possible values are
rs232
,
v35
,
rs422
, and
v11
.
ClockMode
A read-write field that displays the clock mode.
The possible values are
notApplicable
,
internal
,
external
,
txExternal
, and
derived
.
Only TDM sync can use a value of
derived
. If the
port is async,
notApplicable
will be displayed.
notApplicable
should not be set.
CtsOOS
A read-write field that displays the CTS service
condition. The possible values are
forceOff
,
forceOn
, and
freeze
.
Data Port Status