Specifications
Table Of Contents
- Title
- Notice
- Contents
- Introduction
- Performance Views
- Interface Device View
- Device Topology View
- Applications Views Summary
- St1kNodeApp
- ST1kAccessApp
- ST1kModuleApp
- ST1kLgmApp
- ST1kFsmApp
- ST1kSgmApp
- ST1kAd10App
- ST1kRtmApp
- ST1kChnlApp
- ST1kINLApp
- ST1kFrmRlyApp
- ST1kBundleApp
- ST1kE1PortApp
- ST1kT1PortApp
- ST1kSdmPortApp
- ST1kAsmApp
- ST1kVoiceApp
- ST1kAsmX50App
- ST1kDsmApp
- ST1kDsmPortApp
- ST1kAlarmApp
- Device Configuration View
- Model Information Views
- Index

ST1kModuleApp Port Status Administration
SPECTRUM Enterprise Manager 56 of 194 Ascom TimePlex ST-1000
Condition
A read-only field that displays either
normal
,
exception
, or
undefined
.
SubCondition
A read-only field that displays one of the following
values.
Port type
A read-only field that gives the port type.
LoopbackDuration
A read-write field having a value ranging from
0
to
65535
, with
65535
specifying a permanent
loopback.
LoopbackStatus
If the port is in loopback, this field indicates the
type of loopback. If the port is not in loopback,
then
none
is displayed.
LoopbackInitiator
If this field displays
local
, loopback was initiated
by a user; if
remote
is displayed, loopback was
initiated by the network. If no loopback is
enabled, this field displays
not applicable
.
Port Address
A read-only port address string.
Error Indication
A read-only field having a value of
set
or
clear
.
SevereIndication
A read-only field having a value of
set
or
clear
.
BGDiagResults
The results of port background diagnostics.
undefined inl failure configuration download
failure
no framer bandwidth
exceeded
none msg timeout server loopback
red alarm cfg mismatch exceed power spec
yellow
alarm
dnload rmt external loopback
LMI fail st to st remote end reset
clock fail los And ros ber over fail threshold
los notify CRC layer2 timeOut
ros err CRC layer2 mismatch
pending disruptive oper connected to test port
oos loss Of signal ds0 disconnect alarm
loss Of pwr