SPECTRUM Enterprise Manager 52 of 194 Ascom TimePlex ST-1000
1 = (lsb of each byte) Register accesses, 2 =
port Loopback, 3 through 8 = reserved
There are no port diagnostics for NCP, SDM,
SGM, and BRM. The default is to ignore all tests.
The following additional fields are found in the
Detail view.
StartDiagMaskExt
This mask allows a module to be online or
standby even though some items as marked by
the mask have failed startup diagnostics. For all
tests, a bit set to 1 means the module will not
operate if the corresponding hardware is not
working. For all test descriptions, bit 1 refers to
the least significant bit of the lowest byte in the
octet string.
Startup diagnostics mask bits for the NCP.
NOTE: This is a continuation of the tests
defined for the NCP in StartDiagMask.
1 = DSM RTS, 2 = LGM RTS, 3 = E3M RTS, 4
= BRM RTS, 5 = checksum for dynamic allo-
cation database, 6 = VFM RTS, 7 through 32
= reserved
Currently, this attribute is not used for any other
module type except the NCP (that is, all bits are
reserved for the other module types).
BgDiagMaskExt
This mask allows a module to be online or
standby even though some items as marked by
the mask have failed background diagnostics. For
all tests, a bit set 1 means the module will not
operate if the corresponding hardware is not
working. For all test descriptions, bit 1 refers to
the least significant bit of the lowest byte in the
octet string.
Background diagnostics mask bits for NCP
NOTE: This is a continuation of the tests
defined for the NCP in BgdDiagMask.
1 = DSM RTS, 2 = LGM RTS, 3 = E3M RTS, 4
= BRM RTS, 5 = checksum for dynamic allo-
cation database, 6 = VFM RTS, 7 through 32
= reserved
Currently, this attribute is not used for any other
module type except the NCP (that is, all bits are
reserved for the other module types).
DiagnoseMode
Used to control module-specific code for
diagnosing problems. The interpretation of values
for this field is determined by the specific type of
module in the slot. The value
0
(the default value)
means normal operation for all module types.