Specifications

Table Of Contents
ST1kModuleApp Slot Configuration
SPECTRUM Enterprise Manager 49 of 194 Ascom TimePlex ST-1000
For BRM modules
BRM-8/U = 1, BRM-8/S = 2, BRM-4/U = 3,
BRM-4/S = 4
Redundant Mod
Server modules always have group redundancy
regardless of the value of this field. The default
value is
none
for I/O modules and
group
for
server modules. The other possible value is
one-
to-one
.
Group ID
An integer value from
1
through
64
. This field
applies to server modules only for group
redundancy.
MaxBypass
The FSM or DSM module bypassing capability in
terms of percentage (0 to 100).
MaxSource
The FSM module termination capability in terms
of percentage (0 to 100).
StartDiagMask
This mask allows a module to be online or
standby even though some items as marked by
the mask have failed startup diagnostics. For all
tests, a bit set 1 means the module will not
operate if the corresponding startup diagnostic
has failed. For all test descriptions, bit 1 refers to
the least significant bit of the lowest byte in the
octet string. The bit descriptions are as follows:
Startup diagnostics mask bits for the NCP are
listed below.
NOTE: Additional tests for the NCP are
defined in StartDiagMaskExt in the Details
view. NCP will ignore bits 1, 3, 4, 7, 8, 10-15,
and 25-31. Bit 24 is no longer used as of revi-
sion 2.0.1.
Bit Attribute Bit Attribute
1 ID PROM 17 E1M RTS
2 LAN RAM 18 FSM RTS
3 Mailbox RAM 19 MIB schema
4 Frame RAM 20 SDM RTS
5 CPI port 21 SGM RTS
6 Modem port 22 ASM RTS
7 ABPI 23 RTM RTS
8 unexp interrupt 24 Utility
9 Ethernet chip 25 Boot PROM
10 DBPI 26 Flash PROM map
11 PARB 27 NCP image
12 Security MIB Db 28 Ticker
13 Resource MIB Db 29 DRAM
14 Alarm MIB Db 30 reserved
15 Database version 31 Clock
16 T1M RTS 32 reserved