Specifications

Table Of Contents
St1kNodeApp Nest Administration
SPECTRUM Enterprise Manager 30 of 194 Ascom TimePlex ST-1000
Addr
The nest address.
Status
A read-only field having
initializing
,
online,
and
failed
as possible values.
Condition
A read-only field having
normal
and
exception
as possible values.
Num Modules
An integer value from
1
to
17
.
Power
The power supply condition, either
good
or
fail
.
Fan
The fan condition, either
good
or
fail
.
Temperature
The temperature condition, either
good
or
tooHigh
.
Clk Ref1
The Clock Reference 1 status, either
enable
or
disable
.
Clk Ref2
The Clock Reference 2 status, either
enable
or
disable
.
Bus Loopback
The Bus Loopback status, either
leftEnable
,
rightEnable
, or
disable
.
SlotPresence
The lsb of the second octet represents slot 1 and
the msb of the first octet represents slot 16. Slot
17 always has an RXM. Each bit set to 1 indicates
that a module is present in that slot.
Active Right
A read-only value equal to
circuit1
or
circuit2
.
Active Left
A read-only value equal to
circuit1
or
circuit2
.
Rxm Ckt1
The Rxm Circuit 1 status, either
pass
,
fail
or
noRxm
.
Rxm Ckt2
The Rxm Circuit 2 status, either
pass
,
fail
or
noRxm
.
Lxm Ckt1
The Lxm Circuit 1 status, either
pass
,
fail
or
noLxm
.
Lxm Ckt2
The Lxm Circuit 2 status, either
pass
,
fail
or
noLxm
.