ST1kT1PortApp T1M Port Configuration
SPECTRUM Enterprise Manager 131 of 194 Ascom TimePlex ST-1000
Bundle Map
A read-write octet string. Each byte represents a
DS0 in a T1 Port, starting with
1
from the right
most byte. The bundle is identified by the number
of the lowest DS0 of the bundle.
EQUGain
A read-write field having the value
g26db
or
g36db
(the default value).
Error Threshold
A read-write value ranging from
0
to
65535
(the
default value).
Severe Threshold
A read-write value ranging from
0
to
65535
(the
default value).
Alarm Threshold
A read-write value ranging from
1
to
9.
The
default value is
3
. If port BER quality is below this
threshold for four seconds, a Port Error alarm will
be sent.
Fail Toggle Request
A read-write field having a value of
noToggle
or
toggleIfPortFail
(the default value).
OOSBit Pattern
A read-write field having a value of
x7e
,
x1a
,
xd5
,
or
x7f
(the default value).
OOSA Signalling
A read-write field having a value of
space
,
mark
,
spaceMark
(the default value), or
markSpace
.
OOSB Signalling
A read-write field having a value of
space
,
mark
,
spaceMark
(the default value), or
markSpace
.
OOSCD Signalling
A read-write field having a value of
spaceSpace
,
markMark
,
spaceMark
(the default value), or
markSpace
.
Signal Version
A read-write field having the value
inverted
or
normal
(the default value).
Fail Threshold
A read-write value from
1
to
9
. If port BER quality
is below this threshold for ten consecutive
seconds, a Port Down alarm will be sent. The
default value is
2
.