Specifications

Table Of Contents
ST1kE1PortApp E1M Port Configuration
SPECTRUM Enterprise Manager 128 of 194 Ascom TimePlex ST-1000
Bundle Map
A read-write octet string. Each byte represents a
DS0 in an E1 Port, starting with 1 from the right
most byte. The bundle is identified by the number
of the lowest DS0 of the bundle. If framing is
g732s, time slot 16 is reserved to be a signaling
byte.
Transmit E Bit
A read-write field with a value of
enable
or
disable
(the default value).
Receive E Bit
A read-write field with a value of
monitor
or
ignore
(the default value).
Fail Threshold
A read-write value from
1
to
9
, with
2
being the
default value. If port BER quality is below this
threshold for ten seconds, a Port Down alarm will
be sent.
Error Threshold
A read-write value from
0
to
65535
(the default
value).
Severe Threshold
A read-write value from
0
to
65535
(the default
value).
Alarm Threshold
A read-write value from
1
to
9
. If port BER quality
is below this threshold for four seconds, a Port
Error alarm will be sent. The default value is
3
.
Fail Toggle Req
A read-write field giving the toggle request as
toggleIfPortFail
(the default value) or
noToggle
.
OOSBit Pattern
A read-write field having a value of
x7f
,
x1a
,
xd5
(the default value), or
x7e
.
OOSA Signalling
A read-write field having a value of
space
,
mark
,
spaceMark
(the default value), or
markSpace
.
OOSB Signalling
A read-write field having a value of
space
,
mark
,
spaceMark
(the default value), or
markSpace
.
OSCD Signalling
A read-write field having a value of
space
,
mark
,
spaceMark
(the default value), or
markSpace
.
Signl Version
A read-write field having the value
inverted
or
normal
(the default value).