Specifications
Table Of Contents
- Title
- Notice
- Contents
- Introduction
- Performance Views
- Interface Device View
- Device Topology View
- Applications Views Summary
- St1kNodeApp
- ST1kAccessApp
- ST1kModuleApp
- ST1kLgmApp
- ST1kFsmApp
- ST1kSgmApp
- ST1kAd10App
- ST1kRtmApp
- ST1kChnlApp
- ST1kINLApp
- ST1kFrmRlyApp
- ST1kBundleApp
- ST1kE1PortApp
- ST1kT1PortApp
- ST1kSdmPortApp
- ST1kAsmApp
- ST1kVoiceApp
- ST1kAsmX50App
- ST1kDsmApp
- ST1kDsmPortApp
- ST1kAlarmApp
- Device Configuration View
- Model Information Views
- Index
ST1kINLApp Inter Nodal Link Configuration
SPECTRUM Enterprise Manager 110 of 194 Ascom TimePlex ST-1000
1 The sum of the bandwidth for all TDM
channels is equal to or less than
MaxTDMDS0
2 The sum of the CIR for all packet channels is
equal to or less than MaxPktDS0 multiplied
by P.
3 The sum of the bandwidth for all TDM
channels plus 1/P multiplied by the SUM of
all packet channel CIR is equal to or less than
the INL bandwidth.
MaxTDMDSO
A read-write value ranging from
1
to
31
representing the maximum TDM bandwidth in
units of DS0. (INL bandwidth minus the value of
MaxTDMDS0 equals the guaranteed packet
bandwidth.
Group
Up to seven groups for each INL. The bit map (bits
1
(lsb) to
7F)
indicates the group(s) of the INL.
The default value is
7F
.
Cost
A read-write value ranging from
1
to
65535
assigned by you. The default value is
1
.
Encryption
A read-write value of either
normal
(the default
value) or
encrypted
.
SateliteHop
A read-write value ranging from
0
to
3
, with
0
being the default value.
OOSTimer
A read-write value ranging from
1
to
60
(with
10
being the default) that indicates the number of
seconds that the ST-1000 will wait after detecting
an out-of-service condition on an INL before
declaring the INL to be out of service and
disconnecting all channels connected over the
INL.
Orig
A read-write value of
yes
or
no
(the default value)
for EMS usage.
RemNodeId
A read-write value for the node identification, with
0
meaning “don't care.” The default value is
0000h
.
RemINLId
A read-write value ranging from
0
to
31
and
indicating the INL number of the remote side.
0
(the default value) means “don't care.”
Part.Id
A read-only value of the partition identification
used by the security server to enforce shared
node.