Switch User Manual
Configuring Voice Ports 12-11
SmartSwitch 1800 Voice Configuration
Forward Delay
This parameter is relevant only if Forwarded Digits (see below) is set to All or 
Extended. It speciÞes the time (in 0.25 second increments) for two delays:
¥ the delay before extended digits are forwarded;
¥ the length of a pause that can be inserted in an extended dial string that is 
being forwarded. Each time a comma is encountered in an extended string, the 
SmartSwitch 1800 will pause for the length of time conÞgured for Forward 
Delay before additional extended digits are forwarded.
The default value for this parameter is 2 (0.5 seconds).
Make Ratio
This parameter is relevant only if Forwarded Digits (see below) is set to All or 
Extended and Forwarded Type (see below) is set to Pulse. It speciÞes the make 
ratio of each digit pulse that is forwarded. Make periods are the times contact is 
made for each digit.
Valid values are 20-80 (in increments of 2); the default value is 34.
Break Ratio
This parameter is relevant only if Forwarded Digits (see below) is set to All or 
Extended and Forwarded Type (see below) is set to Pulse. It speciÞes the break 
ratio of each digit pulse that is forwarded. Break periods are the times contact is 
broken between digits.
Valid values are 80-20 (in increments of 2); the default value is 66.
DTMF On Duration
This parameter is relevant only if Forwarded Digits (see below) is set to All or 
Extended and Forwarded Type (see below) is set to DTMF. This speciÞes the 
length (in milliseconds) of a tone that will be used to produce a single DTMF 
digit. The default value for this parameter is 100.
DTMF Off Duration
This parameter is relevant only if Forwarded Digits (see below) is set to All or 
Extended and Forwarded Type (see below) is set to DTMF. This speciÞes the 
length (in milliseconds) of silence between DTMF tones in a dial digit string. The 
default value for this parameter is 100.
Auto Dial
This parameter enables or disables the auto-dial feature of the SmartSwitch 1800. 
If auto-dialing is enabled, the SmartSwitch will dial the conÞgured Auto Dial 
Number (see below) when the handset attached to this voice port is taken 
off-hook. The default value for this parameter is Disabled. Enabling this 
parameter will disable the variable length dialing feature for this channel, 
regardless of the Dial Timer setting (see above).