Specifications
Event and Alarm Messages
FRX4000 and FRX6000 Events and Alarms
FRX4000 and FRX6000
4-8 Management Module Guide
CsEvFormat/Event019d0219
{d "%w- %d %m-, %Y - %T"} -
A port module {I 4} of type {0 3}, does not
match it’s defined type of {0 5} in device
{m} of type {t}. Trap severity is {T
SMC_Severity 1}.
CsPCause/Prob019d0219
PROBABLE CAUSE: A port does not
match its defined type.
RECOMMENDED ACTIONS: 1)
Refer to Event log for port
information. 2) Check module and slot
configuration.
CsEvFormat/Event019d0220
{d "%w- %d %m-, %Y - %T"} -
A port on a module {1 4} of type {0 3}, has
a bad port status in device {m} of type {t}.
Trap severity is {T SMC_Severity 1}.
CsPCause/Prob019d0220
PROBABLE CAUSE: A port on this
module has a bad port status.
RECOMMENDED ACTIONS: 1)
Refer to Event log for port
information. 2) Check cable
connections.
CsEvFormat/Event019d0221
{d "%w- %d %m-, %Y - %T"} -
A Duplicate MAC Address has been
detected on FDDI ring attached to device
{m} of type {t}. Trap severity is {T
SMC_Severity 1}.
CsPCause/Prob019d0221
PROBABLE CAUSE: Two or more
stations with the same MAC address
were detected on the network.
RECOMMENDED ACTIONS: MAC
address must be unique on the
network. 1) Locate the offending
stations and change the adaptor
cards.
Table 4-1. Events and Alarms (Continued)
Message in the Event Log
Alarm View Probable Cause
Message