Specifications
9032285 E1
4-5
Event and Alarm Messages
FRX4000 and FRX6000 Events and Alarms
CsEvFormat/Event019d0100
{d "%w- %d %m-, %Y - %T"} - 
For device, {m}, reports the diagnostic 
error, {0 3}. Trap severity is {T 
SMC_Severity 1}.
CsPCause/Prob019d0100
No probable cause message.
CsEvFormat/Event019d0200
{d "%w- %d %m-, %Y - %T"} - 
A FDDI port on device, {m} of type {t} has 
detected an attachment configuration 
change. The new state is {T 
FDDISMTCFState3}. Trap severity is
{T SMC_Severity 1}.
CsPCause/Prob019d0200
PROBABLE CAUSE: The FDDI MAC 
physical connection has changed.
RECOMMENDED ACTIONS: 1) 
Refer to Event log for current 
attachment state. 2) Check the A and 
B port connections. 3) Check the 
upstream and downstream devices.
CsEvFormat/Event019d0202
{d "%w- %d %m-, %Y - %T"} - 
The AC input for the first power supply 
on device, {m} of type {t} is {T 
SMC_Power 3}. Trap severity is {T 
SMC_Severity 1}.
CsPCause/Prob019d0202
PROBABLE CAUSE: The AC input to 
the unit’s first power supply has 
changed.
RECOMMENDED ACTIONS: 1) 
Refer to Event log for current AC 
input state. If AC input state is bad, 2) 
Check first power supply unit on 
device. 3) Check power source to 
device.
CsEvFormat/Event019d0203
{d "%w- %d %m-, %Y - %T"} - 
The AC input for the second power 
supply on device, {m} of type {t} is {T 
SMC_Power 3}. Trap severity is {T 
SMC_Severity 1}.
CsPCause/Prob019d0203
PROBABLE CAUSE: The AC input to 
the unit’s second power supply has 
changed.
RECOMMENDED ACTIONS: 1) 
Refer to Event log for current AC 
input state. If AC input is bad, 2) 
Check second power supply unit on 
device. 3) Check power source to 
device.
Table 4-1.  Events and Alarms (Continued)
 Message in the Event Log
Alarm View Probable Cause 
Message