Chapter 2: Hardware Installation
18 SmartSwitch Router 2100 Getting Started Guide
2. Place the SSR 2100 on the table, allowing at least 3” of space on each side for adequate
air flow to the cooling fans.
Rack Mount Installation
You can install the SSR 2100 in a standard 19” equipment rack. The SSR 2100 chassis
contains screw holes for front-mounting brackets.
Note:
Never attempt to rack mount the SSR 2100 unaided. Ask an assistant to help you
hold the chassis.
To install the SSR 2100 chassis in an equipment rack, use the following procedure. You
need a phillips-head screwdriver to perform this procedure.
Figure 3 shows an example of how to install the SSR 2100 in an equipment rack. The
procedure following the figure describes how to install the SSR 2100 in an equipment rack.
Figure 3. Installing the SSR 2100 chassis in an equipment rack
To install the SSR 2100 in an equipment rack:
1. If your SSR 2100 is not already equipped with rack-mounting brackets, take the
following steps. Otherwise skip to Step 2.
a. Remove the two screws that help hold the front panel of the SSR 2100 on to the
rest of the chassis. There is one screw located on each side of the chassis very near
the front of the SSR 2100. These screws will be reused to help hold the rack
mounting brackets to the SSR 2100.
b. Align one of the mounting brackets over the corresponding holes in the side of
the SSR 2100. The mounting bracket is correctly positioned when the side with
two open mounting holes is flush with the front of the SSR 2100.
c. Use the phillips-head screwdriver and the supplied phillips-head screws to attach
the mounting bracket to both the side and bottom of the chassis. (There are four
holes for each rack mounting bracket—the one on the side of the chassis that you
exposed in Step a, and three holes in the bottom of the chassis.)
2100
CONSOLE
10/100 MGMT
4
21
Tx
Rx
Link
AN
Tx
Rx
Link
AN
SSR-2-GSX
2
21
Tx
Rx
Link
AN
Tx
Rx
Link
AN
RST
SYS
OK
ERR DIAG
HBT
3
21
Tx
Rx
Link
AN
Tx
Rx
Link
AN
1
21
Tx
Rx
Link
AN
Tx
Rx
Link
AN