Specifications

Table Of Contents
Chapter 2: Hardware Installation
16 SmartSwitch Router 2100 Getting Started Guide
Before performing any upgrade or installation procedures, ensure that the SSR 2100 is
powered off.
Never operate the SSR 2100 if the it becomes wet or the area where it has been installed
is wet.
Preventing Equipment Damage
Observe the precautions listed in this section to prevent accidental damage to the
SSR 2100 components.
Caution
:
To prevent accidental product damage, observe the following precautions:
Always use proper electrostatic discharge (ESD) gear when handling internal parts of
the chassis.
Make sure you allow adequate room for air flow around the SSR 2100.
Hardware Specifications
The following table lists the physical and environmental specifications for the SSR 2100.
Installing the Hardware
This section describes how to perform the following tasks:
Verifying your shipment
Installing the chassis (on a tabletop or in an equipment rack)
Table 7. SSR 2100 physical and environmental specifications
Dimensions Inches: 2.8” (height) x 17” (width) x 18.5” (depth)
Centimeters: 7.1cm x 43.2cm x 47cm
Weight Pounds: 22
Kilograms: 10
Power 100-125 VAC, 2.6 A maximum;
200-240 VAC, 1.3 A maximum
Operating temperature Fahrenheit: 41
o
F to 104
o
F
Centigrade: 5
o
C to 40
o
C