Specifications
rmon alarm
682 SSR Command Line Interface Reference Manual
rmon alarm
Purpose
Configures the RMON 1 Alarm group.
Format
rmon alarm index <index-number> variable <string> [interval <seconds>] [falling-event-
index <num>] [falling-threshold <num>] [owner <string>] [rising-event-index <num>]
[rising-threshold <num>] [startup rising|falling|both] [status enable|disable] [type
absolute-value|delta-value]
Mode
Configure
Description
The Alarm group takes periodic statistical samples and compares them with previously-
configured thresholds. If a monitored variable crosses a threshold, an alarm is generated.
The rmon alarm command sets various parameters of the RMON 1 Alarm control table.
Use the rmon show alarm command to display the alarm data.
Parameters
<index-number>
Is a number that uniquely identifies an entry in the alarm table. The value must be
between 1 and 65535, inclusive.
interval <seconds>
Specifies the sampling interval in seconds when statistical samples of variables are
collected and compared to the rising and falling thresholds. The value must be
between 1 and 2147483647, inclusive.
falling-event-index <num>
Is the action to be taken as defined by the row with this index in the event table when
a falling threshold is crossed. The value must be between 1 and 65535, inclusive.
falling-threshold <num>
Specifies that the sample’s value must be less than or equal to the threshold to trigger