Specifications

2-58 SmartSwitch 6500 Reference Manual
Console Commands
DS3E3LoopBack
Use DS3E3LoopBack to set or display loopback at DS3 or E3 ports.
2p›F A port in loopback mode does not pass normal traffic.
Operators
modify, show
Parameters
Descriptions
Input Parameter Description Value/Field Size Default
[PortNumber] Physical port number on the switch. 1A1 to 8B4 All
[Loopback] Loopback mode (see Table 2-3). None, Cell, Payload,
Line, Diag
None
Output Parameter Description
[Port] Port number on the switch.
[Type] Type of port.
[Loopback] Loopback mode specified (see Table 2-3).
Operator Parameters/Permissions Description
modify
ds3e3loopback
[Port] <port>
[Loopback] <loopback>
Administrator
Sets loopback status of DS3 and E3 ports.