Specifications
2-274 SmartSwitch 6500 Reference Manual
SVC
Use SVC to display SVCs on a port or all ports.
Operator
show
Parameters
Input Parameter Description Value/Field Size Default
[PortNumber] Port number on the switch. 1A1 to 8B4 (for physical ports),
1A1.n to 8B4.n (for virtual ports),
or All
All
Output Parameter Description
[Conn Id] Identifier unique for each connection.
[Low Port] Port receiving the backward flow of the high/low pair.
[Low VPI] Low VPI (virtual path identifier) number.
[LowVCI] Low VCI (virtual circuit identifier) number.
[Low Type] Low port connection type (PMP or PTP).
[High Port] Port sending the forward flow of the high/low pair.
[High VPI] High VPI (virtual path identifier) number.
[High VCI] High VCI (virtual circuit identifier) number.
[High Type] High port connection type (PMP or PTP).
[Creation Time] Time when the SVC was established (with respect to the boot time on the switch).
Displayed in Hour:Minute:Seconds format.