Specifications
Application Views Fore Software Application (ForeSoftWreApp)
Device Management Page 96 ForeRunner ATM Switch Modules
SPVPC Source Table View
Access: From the PNNI SPVC/SPVCP Configuration
view, click on the SPVPC Source button.
This table contains information about SPVPCs
that have their source at this switch. This table
serves the same function that the PNNI SPVC
Source Table serves for SPVCCs.
Name
The name of the port.
Port
The input port of this SPVPC and is the same as
the chanrInputPort, chanPort, pathPort, and
portNumber. The maximum value of this variable
depends on the type of the switch.
VPI
The VPI to be used at the originating switch for
the permanent portion of this SPVPC.
Port
The port where the permanent portion of this
SPVPC resides at the destination switch. It has a
value of -1 if this port at the destination cannot be
determined.
VPI
The VPI to be used at the destination switch for
the permanent portion of this SPVPC. The range
given above is the maximum possible.
Ass’d VPI
The VPI that is assigned at the destination switch
for the permanent portion of this SPVPC. This
value is only meaningful if the SPVPC status is
up.
VPI/VCI Sel
The originating switch for a SPVPC can specify
the VPI to be used for the permanent portion of
this SPVPC at the destination switch. The value of
this object indicates whether the SPVPC was
configured with a specific value for this VPI/VCI
or not. require indicates that the user
configured a specific value for this VPI and
noPref indicates that the user did not specify
any.
Retries
The number of times the call setup has been
attempted since the SPVPC creation or the last
successful call setup for this SPVPC.
Status
The operational status of this SPVPC. The value of
up indicates that this SPVPC is operational and
down indicates that the SPVPC is not-operational.