Specifications
Application Views Fore Software Application (ForeSoftWreApp)
Device Management Page 75 ForeRunner ATM Switch Modules
Max B/W
The maximum bandwidth of this path, in cells per
second.
Allc B/W
The allocated bandwidth of this path, in cells per
second.
Cells
The number of cells transferred over this path.
Uptime
The time since this path was created, in
hundredths of a second.
Protocol
The signaling protocol that created this path.
Additional Detail View
Access: Within the ATM Switch Software Port Detail
View, click the Additional Detail button.
Port Number
The hardware port number of this port. For a
control port (software port), the value of this
object is 0.
Name
The name of this port.
Board
The hardware board number of this port.
Module
The hardware module number of this port. For a
control port (software port), the value of this
object is the maximum number of hardware
modules plus one.
PP Policing CBR
This variable defines the per-port policing
configuration for CBR connections. The states are
defined in Table 19.
PP Policing VBR
This variable defines the per-port policing
configuration for nrtVBR connections. The states
are defined in Table 20.
Table 19: Policing CBR States
State Definition
allOn All CBR connections arriving on this port
will be subjected to GCRA policing.
allOff No CBR connections arriving on this port
will be subjected to GCRA policing.
svcOn All CBR SVCs arriving on this port will be
subjected to GCRA policing.
svcOff No CBR SVCs arriving on this port will be
subjected to GCRA policing. CBR PVCs
will be GCRA policed based on the state
of their UPC contract.