Two methods exist for clearing this yellow alarm condition, depending on the
procedural order in which you created the independent EFDMIM icon and
configured the EFDMIM in the IRM or IRBM hub Device View. The particular
EFDMIM showing the duplicate IP address yellow alarm condition depends
on which EFDMIM was created or configured first. The following sections
describe the two possible ways of creating EFDMIMs and how to clear the
resulting duplicate alarms.
Case #1
1. Create the independent EFDMIM (Bdg_CSI _EFDMIM) icon.
2. Create the IRM or IRBM hub icon that contains the EFDMIM.
3. Configure the EFDMIM in the hub Device View.
If you followed the previous procedure, you can clear the duplicate address
alarm as follows:
1. Navigate to the hub Device View containing the EFDMIM.
2. Click on the EFDMIM to highlight it.
3. Select Icon Subviews from the View menu.
4. Select MIM Diagnostic View to access the EFDMIM Diagnostic View.
5. Select Alarms from the EFDMIM Diagnostic View
. The Alarm View
displays an alarm icon for the EFDMIM installed in the hub with a yellow
alarm contact status color. The Symptom/Probable Cause box displays a
DUPLICATE IP ADDRESS message.
6. Choose the Clear option from the Tools menu to clear the alarm. You can
now exit from this view.
Case #2
1. Create the IRM or IRBM hub icon that contains the EFDMIM.
2. Configure the EFDMIM in the hub’s Device View.
3. Create the independent EFDMIM (Bdg_CSI_EFDMIM) icon.
4. If you followed the previous procedure, the EFDMIM (Bdg_CSI_EFDMIM)
icon appears with a yellow alarm contact status in the Topology View. You
can clear the duplicate address alarm as follows:
5. Click on the stand alone EFDMIM (Bdg_CSI_EFDMIM) icon.
6. Select Icon Subviews from the View menu.