Specifications
9031035 E4 Token Ring and TR Tier Applications
6-5
Token Ring Applications
Token Ring Tier 1 Table
Token Ring Concentrator Card Information View
The Token Ring Concentrator Card Information View provides additional
concentrator card information; the fields not seen in the Token Ring Card
Table are described below:
Ring Number
The ring number assigned when configuring a bridge.
Active Monitor Port
The relative port number of the active monitor for this ring. Its value is 0 if
the active monitor is not attached to any port on this concentrator.
Auto Partition Enable Timer
Indicates the amount of time to wait until re-enabling a beacon detected port.
The default value is 0 seconds.
Auto Partition Hold Timer
Indicates the amount of wait time until starting the beacon detect process.
The default value is 0 seconds.
Auto Partition Retries
Indicates the number of times a port can be temporarily locked by the beacon
detect process prior to being permanently locked. The default value is 3.
Reset Durable User Attributes
A request to copy the default values stored in durable memory to the User
Durable attributes also in durable memory. User attributes effected are Ring
Speed, Allow Insert, Forced Insert, Auto Partition Hold Timer, Auto Partition
Retries, and Auto Partition Enable Timer. A description of the types of the
Reset Durable User Attributes is listed in Table 6-3.
Token Ring Tier 1 Table
The Token Ring Tier1 Table View provides information about the Token Ring
concentrator card and can be accessed by selecting Tier1 Port Info from the
TR Tier application Icon Subviews menu. This view also provides the Token
Ring Tier1 Table fields.
Model Name
Provides the application name.
Table 6-3. Reset Durable User Attributes Types and Descriptions
Attributes Type Descriptions
resetComplete Reset complete or never requested.
setToDefaults User durable attributes reset to origional
default values.