Specifications

9031035 E4 Hub Applications
5-7
CPU + RAM Application
CPU + RAM Application
The CPU + Ram Application provides the Hub Debug View as the only
additional application-specific view. You may access the Hub Debug View
using either of the following methods:
Select Hub Debug from the CPU + RAM Icon
Subviews menu
Once the CPU + RAM icon is highlighted, select Hub
Debug from the View Icon Subviews menu to open the
Hub Debug View.
The fields for the CPU + Ram Application are described below:
Model Name
Provides the model name.
Network Address
Provides the Ungermann Bass hub IP address.
The Board Diagnostic Table is provided in this view and is described below:
Slot
The relative slot position of a card starting at 1.
Message
A text message describing a power-on diagnostic state. Possible states are n/a
(not available), noFault, parityErr, networkErr, diagErr, and operationErr.
Fault
Faults detected by the module.
Halt Reason
The last specific halt reason detected by the card.
To access additional debug register statistics, click on any column in this
table.
Access/One Board Debug View
You may access similar Access/One information by double-clicking on any
column entry in the Access/One Hub Debug View. An additional field is
described below:
Debug Registers
A set of 14 80186 registers used for debugging purposes. These are CS, IP,
FLAG, AX, BX, CX, DX, SP, BP, SI, DI, DS, ES, and SS.