Port Id
The relative position of a port within a card starting with 1. The AUI port
identifier is 13.
Link Test Status
The result of the link integrity test. The Link Test Status types and
descriptions are listed in Table 4-5.
Link Test Action
A request to unlock the link integrity test, which is a continuous test. The
Link Test Status types and descriptions are listed in Table 4-5.
Ether Conc Fib Application
The Ether conc 10bt application supports the following application-specific
views:
Ethernet Fiber Port Table View
Ethernet Fiber Port Table Entry View.
These views provide similar informational fields. These views are described
below:
Ethernet Fiber Port Table View
You can open the Ethernet Fiber Table View by selecting port-table from the
Ether Conc Fib Icon Subviews menu, or by highlighting the Ether Conc Fib
icon, opening the Views menu, and selecting Port Table from the Icon
Subviews menu. This view and the Ethernet Fiber Port Table Entry View
provide similar informational fields; the Ethernet Fiber Port Table View
allows you to sort, find, or update the view. The fields for both views are
described below.
Table 4-5. Link Test Status Descriptions
Link Test Status Description
testLocked 10BaseT Link integrity test
(Administrativelylocked )
testFailed 10BaseT Link integrity test failed
testPassed 10BaseT Link integrity test passed