Specifications

Ethernet Applications
Monitor Ether Application
Ethernet Applications Ungermann Bass Hub
4-14 Management Module Guide
Late Collisions
Counts the number of times any port in this group had transmit and receive
active concurrently but late. Simultaneous late collisions on multiple ports are
counted as only one group late collision.
Address Tracking Table
You can access the Address Table View by clicking Address Tracking from the
Monitor Ether icon subviews menu. The fields for this table are described
below:
Slot
The relative slot number in an enclosure starting with 1.
Port
The relative position of a port within a card starting with 1. The AUI port
identifier is 13.
MAC Address
The physical address for this hub.
Changes
The relative number of changes for this port.
Port Diagnostic Table
The fields for this table are described below.
Slot
The relative slot number in an enclosure starting with 1.
Port
The relative slot number in an enclosure starting with 1.
Bad Pkts
The number of times that a packet has been received with the transmission
frequency (data rate) detectably out of spec. This count may, but does not have
to, include packets that were still able to be repeated.
A sum of hmMonPortFrameCheckSeqErrors, hmMonPortFramesTooLong,
and hmMonPortAlignmentErrors.
Short
A carrier-sense event that lasts longer than 0 microseconds but less than or
equal to 7.4 microseconds increments this counter. A carrier-sense event that
lasts longer than 7.4 but less than 8.2 microseconds increments either this
counter or the hmMonPortRunts counter, but not both.