Specifications
Ethernet Applications
EWA Monitor Application
Ethernet Applications Ungermann Bass Hub
4-8 Management Module Guide
Link Test
The result of the latest link integrity test. Note that this does not apply to an
AUI port. Returns Failed, Passed, or notApplicable.
Admin State
The administrative state of the 10BaseT link integrity function. When locked,
the port functions like an ASP-300. Note that this does not apply to an AUI
port.
Polarity
Indicates if the transmit/receive polarity of the twisted pair port was
determined to be incorrect and then automatically corrected. Note that this
does not apply to an AUI port.
Type
Indicates the type of interface between the (physical) port to the physical
medium.
Clicking on an entry in the Ethernet Extended Port Table opens the Port
Configuration Table.
Port Configuration View
The fields for this view are similar to the fields in the Ethernet Basic Port
View. Link Integrity Tests allow you to toggle on or off the result of the latest
link integrity test.
EWA Monitor Application
The EWA (exponentially weighted average) Monitor Application supports the
following additional sub-application views:
• Ethernet Monitor View
• Monitor Context Information View
• Ethernet Context View
• Context Information View
These views are described in the following sections: