Specifications

9031035 E4 Event and Alarm Messages
9-5
Ungermann Bass Hub Events and Alarms
001b0038
Access/One hub model {m}: One or more of
the concentrator’s ports are experiencing a
lobe fault. The concentrator experiences
voltage (either positive or negative) in only
one of the phantom pair wires.
001b0038
1) Cable problem.
2) Hardware problem on a device
connected to the port.
001b0039
Access/One hub model {m}: One or more of
the concentrator’s ports are no longer
experiencing a lobe fault.
Not applicable
001b0040
Access/One hub model {m}: The link test on
one or more of the concentrator’s ports has
been unlocked.
Not applicable
001b0041
Access/One hub model {m}: The link test on
one or more of the concentrator’s ports has
been locked.
Not applicable
001b0048
Access/One hub model {m}: At least one
power module has lost its AC power. Its state
changed to acPowerAbnormal.
001b0048
1) AC power supply lost.
2) Hardware problem on power supply
module.
001b0049
Access/One hub model {m}: The temperature
of the power supply has become too high. Its
state changed to highTemp.
001b0049
1) Defective fan.
2) Airflow obstruction.
3) Environment temperature too high.
001b0050
Access/One hub model {m}: One or more of
the interfaces to the network backbone are
experiencing faults. Its state changed to
netOrSupLoopback.
001b0050
1) Connection to the backbone is bad.
2) Backbone is faulty.
3) Faulty network interface.
Table 9-1. Events and Alarms (Continued)
Event Message Probable Cause Message