Clearing Duplicate Address Alarms for the LANtern NMM
Two methods exist for clearing this yellow alarm condition depending on the
procedural order in which you created the independent LANtern NMM icon
and configured the LANtern NMM in the IRM or IRBM hub Device View. The
particular LANtern NMM showing the duplicate IP address yellow alarm
condition depends on which LANtern NMM was created or configured first.
The following sections describe the two possible ways of creating LANtern
NMMs and how to clear the resulting duplicate alarms.
Case #1
1. Create the independent LANtern NMM (NA_Nov_LANMIM) icon.
2. Create the IRM or IRBM hub icon which contains the LANtern NMM.
3. Configure the LANtern NMM in the hub’s Device View.
If you followed the above procedure, you can clear the duplicate address alarm
as follows:
1. Go into the hub’s Device View containing the LANtern NMM.
2. Click on the LANtern NMM.
3. Select Icon Subviews from the View menu.
4. Select MIM Diagnostic View to access the LANtern NMM Diagnostic
View.
5. Select Alarms from the LANtern NMM Diagnostic View. The Alarm
View displays an alarm icon for the LANtern NMM installed in the hub
with a yellow alarm contact status color. The Symptom/Probable Cause
box displays a DUPLICATE IP ADDRESS message.
6. Select the Clear button to clear the alarm. The Alarm View clears and
you can now exit from this view.