Specifications
SPECTRUM Installation Program
Known Installation Anomalies in SPECTRUM 6.0.3
SPECTRUM Software Release Notes Page 78
if you used the WIN2000 User Manager to view your Group permissions
and then click OK. This is an unexpected behavior in Windows 2000 and
has been brought to the attention of Microsoft (case #SRX000428601204).
Solution: Login as an Administrator and re-add the user(s) to the
Administrators User Group.
Problem 3: When you run host_eval on Windows NT with a foreign
operating system, you receive a message warning that you have a missing
operating system patch and to contact your system administrator to
correct the problem. This warning appears when host_eval fails to detect
either Service Pack 5 or 6.
Solution: Service Packs 5 or 6a are required to run SPECTRUM.
Problem 4: On the Solaris platform, SPECTRUM cannot be installed in the
/opt/SPECTRUM directory.
Solution: This problem will be addressed in a future release of
SPECTRUM.
Problem 5: On the Windows NT platform, you are not allowed to perform
an installation into a directory that contains a space. You are forced to
install into the win32app as the default directory.
Solution: This problem will be addressed in a future release of
SPECTRUM.
Problem 6: On Windows NT, if the DISPLAY environment variable is set,
the eXceed server (eXceed 6.2) will not start automatically causing
SpectroGRAPH and other X applications not to start.
Solution: Aprisma is in progress of debugging this problem for a solution.
Problem 7: On Solaris 2.7 platform, when you upgrade in place from
SPECTRUM 5.0rev1with CS3 MMS3 to SPECTRUM 6.0, the installation
fails because the SpectroSERVER and Archive Manager were never run
prior to the migration. You receive the error message,
** Error during Creation of DDM database save file
The ddm_save program fails to save a database which never had data
archived to it. Users normally do not migrate empty databases.