Specifications
Enterprise Alarm Manager
Known Alarm Manager Anomalies in SPECTRUM 6.0.3
SPECTRUM Software Release Notes Page 46
Problem 11: When you run Enterprise Alarm Manager (within a
distributed environment) against a SpectroSERVER which does not have
all model types linked in and which is modeling a landscape which
contains some of these extra model types, the extra model types will not
show up in the model type list of the filter dialog, but any alarms on the
extra model types will be displayed in the alarm list.
Solution: Be sure the server has all model types (within a distributed
environment) needed to display in the model type list.
Problem 12: When changing column sizes while the Model list is
updating, the EAM application will crash.
Solution: Wait until the Model list completes updating and then resize
columns. This has been found to be related to Neuron Data which has this
case under review (case # 45409).
Problem 13: If the Model menu or the Icon Subviews menu (accessed by
right clicking the device icon) is open at the time the device is removed from
the view (for example, the alarm is cleared or the device is destroyed),
accessing the menu causes the application to crash.
Solution: If the Model or Icon Subviews menu is open when the device is
removed from the view, close the menu (release the right mouse button or
click elsewhere in the view) and reopen the menu for the newly selected
item. Aprisma and Neuron Data are continuing to investigate a fix or
workaround for this problem.
Problem 14: When using the Enterprise Alarm Manager (EAM) on
systems running Windows NT, 4.0, and 2000, if you hit the Return or
Enter keys while entering a text string in the Alarm Status field, the data
reflected in the Alarm Status field in the AlarmNotifier will be truncated or
include garbage characters. In addition, the values for fields following
Alarm Status in the AlarmNotifier will also contain garbage characters.
This is a problem if you are using AlarmNotifier in conjunction with EAM.
Solution: Do not press the Return or Enter keys while entering text in
the Alarm Status field since text will automatically wrap. This problem will
be corrected in the next major release of SPECTRUM.