Specifications

Serial I/f Application Configuration
Mrm Resilience
Application Views 3Com LinkSwitch 1000/3000
5-40 Management Module Guide
Table 5-17 shows possible values and descriptions.
Mrm Resilience
This application provides access to the Mrm Resilience Table view. The model
for this application is 3CommrmResApp.
Mrm Resilience View
This view provides the Mrm Resilience Table and the following buttons:
Flush Table
Setting this field to flush empties the Resilience Table. Once flushed no
resilient links are configured. You can now configure new links.
This button opens the Add Resilient Table Entry view. Enter the Instance of
the new pair and set the Under Mod field to Under-Mod. This creates an
empty entry in the table. Double-click the entry to be able to enter the
definition.
This button opens the Mrm Resilience Standby Table.
Mrm Resilience Table
A device can be configured to have a number of “resilient pairs” 802.3 Point-to-
Point connections; for example, UTP, that allow two repeaters to be connected
together in a resilient configuration. In such a pair, one port is the main port,
Table 5-17. Row Status Values
Value Description
Active This status can be displayed and set
NotinService This status can be displayed and set
NotReady This status can be displayed but not set
Create&Go Used only when adding entries
Create&Wait Used only when adding entries
Destroy Deletes the entry
Add Entry
StandBy Map Table