Specifications

9032294 E2 Application Views
5-13
Hub Application
Poll Table
Poll Table
This application provides access to the Poll Table view, which presents a table
containing polling information for this device. The model type for this
application is 3CompollApp.
Poll Table View
This view contains the Poll Table, the Next Free Index field, and the Add
Entry button.
Next Free Index
Displays the index number for the next table entry
Accesses the Poll Table Entry view in which you can add table entries and set
the Row Status for this new entry.
Poll Table
This table is used to provide remote device monitoring facilities. It allows a
table of network devices to be set up and polled. Setup variables include
polling interval and protocol. This table can be configured to inform the
management station(s) of devices that are not responding to polls or that have
stated to respond after a period of silence.
The minimal single poll is as follows:
1. In one packet write the Address, Rate=Once-Only, and Row
Status=Create&Go.
2. In the next packet read the Trip Time.
The minimal monitoring of a device is as follows:
1. In one packet write the Address, Rate=30-seconds and Row
Status=Create&Go.
2. Wait for traps to come in.
Add Entry
NOTE
The first row of the table is only used for once-only polls.