Specifications
Hub Application
Gauges Group
Application Views 3Com LinkSwitch 1000/3000
5-10 Management Module Guide
Gauge Owner
Displays the entity that configured this entry and is therefore using the
resources assigned to it. The default is System. You can update this field.
Gauges Group View Fields
In addition to the Gauges Table, this view contains the following:
Table Size
Displays the number of entries in the Gauges Table. This value depends on the
requirements and resources of the device. In practice the maximum will be
approximately 1000.
Next Free Index
Displays the index number that must be used for the next table entry.
Threshold Level Scaler
When the alarm is calibrated automatically, the Threshold is set to this
percentage of the Peak value. The automatic calibration value is computed as
the Peak value divided by this value, times 100. You can update this field to a
value between 1 and 65535.
Recovery Level Scaler
When the alarm is calibrated automatically, the Recovery is set to this
percentage of the Peak value. The automatic calibration value is computed as
the Peak value divided by this value, times 100. You can update this field to a
value between 1 and 65535.
This button accesses the Table Row Update view.
Table Row Update view
This view allows you to update entries in the Gauges Table. Only one attribute
can be modified at a time.
Configure Obj ID
Enter the Object ID of the entry that you want to update.
Configure Column
Select the attribute that you want to update. Possible values are provided at
the bottom of the view. The entries in the list change depending on the Object
ID selected.
Configure Value
Enter the new value for the selected attribute. Possible values are provided at
the bottom of the view.
Table Update