Specifications
9032294 E2 Application Views
5-9
Hub Application
Gauges Group
Gauge State
Displays the current state of the alarm. You can update this field. Table 5-5
lists possible values and descriptions of them.
3 Disable
4 Enable
10 NotifyAndEnablePort
11 NotifyAndEnableCard
16 EnablePort
17 EnableCard
21 NotifyPollSuccess
23 NotifyUnFilterBridgePort
Table 5-4. Gauges Recovery Actions (Continued)
Value Action
Table 5-5. Gauge State Values
Value Description
OnTriggersEnabled The normal activity state of the alarm. The value is
updated on every sample. If it crosses the Threshold or
Recovery level the corresponding action is taken.
OnTriggersDisabled Used when a new device or alarm is set up and the
Threshold and Recovery values have not been calibrated.
The alarm runs as normal and the Value and Peak fields
are updated, but no action is taken.
Off Deactivates the alarm. This allows it to be configured
safely.
Deleted Invalidates the alarm. Values are no longer updated.
AutoCalibrate Updates the Threshold and Recovery fields according to the
current Peak value. The State then becomes
onTriggersEnabled. This can not be set while the alarm is
deleted.
After autoCalibration:
Threshold = Peak * Threshold Level Scaler
Recovery = Peak * Recovery Level Scaler
When the State is either onTriggersEnabled or
onTriggersDisabled, all fields for the alarm are validated. If
any of the fields are invalid the operation will fail.
The sampling data, Value, Peak and State can be reset by
setting this field to onTriggersEnabled, onTriggersDisabled
or autoCalubrate when it is in either of the “on” states.