Specifications

Ethernet Configuration
Configuration Views SynOptics Series 3000 Hub
3-8 Management Module Guide
Condition
Conditions that set off the threshold. The possible values are:
other- None of the following.
crossValue- The actual value crosses the set value (i.e., either from lower
to higher or higher to lower).
overValue- The actual value/sec is greater than the set value/sec.
overRate- The rate of the Actual Value/second is greater than the Set
Value/second.
phantomOn- The phantom signal of the port has changed to On.
phantomOff- The phantom signal of the port has changed to Off.
The values threshold Condition can have is actually dependent on the value of
the threshold Type. Table 3-1 shows the valid combinations between the two
objects.
When the condition specified is crossValue or overValue, the Actual value is
accumulated from the beginning of the duration window and is checked every
five seconds.
When the condition specified is overRate and the duration is less than or
equal to five seconds, the Actual value is based on the data accumulated
during the five second sampling period.
Table 3-1. Threshold Condition
Threshold Type Allowed Values for Threshold Condition
lineError (2) Possible values are 2,3, or 4.
burstError (3) Possible values are 2,3, or 4.
arcFciError (4) Possible values are 2,3, or 4.
recvCongestionErr (5) Possible values are 2,3, or 4.
frameCopyError (6) Possible values are 2,3, or 4.
tokenError Possible values are 2,3, or 4.
lostFrame (8) Possible values are 2,3, or 4.
beaconing (9) Possible values are 2,3, or 4.
goodOctets (10) Possible values are 2,3, or 4.
goodFrames (11) Possible values are 2,3, or 4.
utilization (12) Possible values are 2 or 3.
stationInserts (13) Any value is possible.
stationDeinserts (14) Any value is possible.
portPhantomStatus (15) Possible values are 5 or 6.