7F06-02 FDDI SmartSwitch™ Interface Module User’s Guide Title Page 903 9031672-02
Only qualified personnel should perform installation procedures. NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice.
Notice DOC NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
Notice CABLETRON SOFTWARE PROGRAM LICENSE 1. LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement. You may not copy, reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron. 2. OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the Program. 3. APPLICABLE LAW.
Notice DECLARATION OF CONFORMITY Application of Council Directive(s): Manufacturer’s Name: Manufacturer’s Address: European Representative Name: European Representative Address: Conformance to Directive(s)/Product Standards: Equipment Type/Environment: 89/336/EEC 73/23/EEC Cabletron Systems, Inc. 35 Industrial Way PO Box 5005 Rochester, NH 03867 Mr. J.
CONTENTS CHAPTER 1 INTRODUCTION 1.1 Using This Manual....................................................................... 1-1 1.2 The 7F06-02 Module ................................................................... 1-1 1.2.1 Cable Type and FPIMs ................................................... 1-2 1.2.2 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch and the 7C04-R Workgroup SmartSwitch.................................................................... 1-3 1.3 Features .......................
Contents CHAPTER 5 TECHNICAL SPECIFICATIONS 5.1 Standards.....................................................................................5-1 5.2 EMI...............................................................................................5-1 5.3 EMC .............................................................................................5-1 5.4 Network Interfaces .......................................................................5-1 5.5 Safety...............................................
CHAPTER 1 INTRODUCTION Welcome to Cabletron Systems 7F06-02 FDDI SmartSwitch Interface Module User Guide. This guide is a simple reference for installing and using the 7F06-02 Module. Before installing this module, you should carefully read through this manual to gain a full understanding of its capabilities. The 7F06-02 Module is a two-port FDDI module. This module connects to a network and the 7X00 SmartSwitch™ Control Module in the 7C03, 7C04 or 7C04-R MMAC SmartSwitch via a SmartSwitch bus. 1.
Chapter 1: Introduction 1.2.1 Cable Type and FPIMs The 7F06-02 module has two front panel connectors that interface to the 7X00 SmartSwitch Module through the chassis backplane. The front panel connections are standard Cabletron FPIMs. There are two FPIMs for each channel. These FPIMs allow the use of single mode or multimode fiber cable with MIC or SC type connectors and twisted pair cable, either shielded or unshielded.
Chapter 1: Introduction 1.2.2 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch and the 7C04-R Workgroup SmartSwitch The 7F06-02 Module is designed to be installed in the 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch or the 7C04-R Workgroup SmartSwitch. The modular design of the 7C03 MMAC SmartSwitch allows other modules that support Ethernet, Fast Ethernet, ATM, FDDI, or Token Ring to be used with the 7F06-02 Module.
Chapter 1: Introduction 1.3.3 Connectivity The 7F06-02 Module has one backplane connection and two sets of A/B front panel FPIM connections. The backplane connection provides power to the 7F06-02 Module and a channel for communication with the 7X00 SmartSwitch Control Module. The two front panel FPIMs provide FDDI connections, allowing the use of single mode or multimode fiber cable with MIC or SC type connectors. 1.
Chapter 1: Introduction 1.5 GETTING HELP If you need additional support related to this device, or if you have any questions, comments, or suggestions concerning this manual, contact the Cabletron Systems Global Call Center: Phone (603) 332-9400 Internet mail support@ctron.com FTP ctron.com (134.141.197.
Chapter 1: Introduction 1-6 7F06-02 FDDI SmartSwitch Interface Module User’s Guide
CHAPTER 2 NETWORK REQUIREMENTS Before installing Cabletron Systems 7F06-02 Module, review the network requirements outlined in this chapter. All requirements included in this chapter should be met to ensure satisfactory performance of the 7F06-02 Module. Failure to do so may result in unsatisfactory network performance. 2.1 FPIM MODULE SPECIFICATIONS This module uses Fiber Port Interface Modules (FPIM) to provide front panel cable connections. The FPIMs are user-installable. Refer to Section 3.
Chapter 2: Network Requirements Table 2-2 Parameter Transmitter Power Parameters Typical Value Worst Case Worst Case Budget Typical Budget 50/125 µm fiber -13.0 dBm -15.0 dBm 13.0 dB 17.5 dB 62.5/125 µm fiber -10.0 dBm -12.0 dBm 16.0 dB 20.5 dB 100/140 µm fiber -7.0 dBm -9.0 dBm 19.0 dB 23.5 dB Error Rate Better than 10-10 The link distance is up to 2 kilometers on the multimode fiber optic cable as specified by ANSI MMF-PMD. 2.1.
Chapter 2: Network Requirements 2.1.3 FPIM-05 and FPIM-07 The FPIM-05 and FPIM-07 provide a single-mode fiber connection. The FPIM-05 uses a MIC style connector and the FPIM-07 uses an SC type connector. The specifications for both devices are listed in Table 2-4. Table 2-4 FPIM-05 and FPIM-07 Specifications Parameter Typical Minimum Maximum Transmitter Peak Wave Length 1300 nm 1270 nm 1330 nm Spectral Width 60 nm - 100 nm Rise Time 3.0 nsec 2.7 nsec 5.0 nsec Fall Time 2.5 nsec 2.
Chapter 2: Network Requirements 2-4 7F06-02 FDDI SmartSwitch Interface Module User’s Guide
CHAPTER 3 INSTALLATION/REMOVAL This chapter contains instructions for unpacking and installing the 7F06-2 Module in the: • 7C03 MMAC SmartSwitch • 7C04 Workgroup SmartSwitch • 7C04-R Workgroup SmartSwitch Also included in the chapter are instructions for installing the front panel FPIMs. 3.
Chapter 3: Installation/Removal 3.2 INSTALLING FPIMS Before installing the 7F06-02 module, attach the antistatic wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package. The 7F06-02 module is shipped without FPIMs. To install an FPIM, follow the procedure below: 1. Remove the module if it is installed in the 7C03 MMAC SmartSwitch chassis by reversing the procedure in Section 3.3. 2. Remove the blank front cover over the FPIM slot. 3.
Chapter 3: Installation/Removal 3.3 INSTALLING/REMOVING THE 7F06-02 MODULE The following procedure details the installation and removal procedure for the 7F06-02 module. 3.3.1 Installing in the 7C03 SmartSwitch The 7F06-02 Module is installed in the 7C03 MMAC SmartSwitch using the following steps and referring to Figure 3-2. Note: The left-most slot in the 7C03 MMAC SmartSwitch is reserved for the 7X00 SmartSwitch Module.
Chapter 3: Installation/Removal 3.3.2 Removing from the 7C03 SmartSwitch The 7F06-02 Module inserted in the 7C03 MMAC SmartSwitch can be removed upon proper removal of power. Follow the steps below and refer to Figure 3-3 to remove the module. Note: Before removing the 7F06-02 module, attach the antistatic wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package. 1.
Chapter 3: Installation/Removal 3.3.3 Installing in the 7C04 or 7C04-R Workgroup SmartSwitch The 7F06-02 Module is installed in the 7C04 or 7C04-R Workgroup SmartSwitch using the following steps and referring to Figures 3-4 and 3-5. Notes: The top slot in the 7C04 Workgroup SmartSwitch is reserved for the 7X00 SmartSwitch Module. The bottom slot in the 7C04-R Workgroup SmartSwitch is reserved for the 7X00 SmartSwitch Module.
Chapter 3: Installation/Removal 1 2 SN 3 4 Screw 7X00 Figure 3-4 SP Ejector Tab Installing the 7F06-02 Module in the 7C04 Workgroup SmartSwitch FANS 4 SP 7A06-01 SN 3 SP 2 7X00 SN SP SP CPU MAC ADR PWR 7F06-02 1 Card Guides 7X00 SN SP CP U 3-6 PW R MAC ADR Figure 3-5 Installing the 7F06-02 Module in the 7C04-R Workgroup SmartSwitch 7F06-02 FDDI SmartSwitch Interface Module User’s Guide
Chapter 3: Installation/Removal 3.3.4 Removing the 7F06-02 from the 7C04 or 7C04-R Workgroup SmartSwitch The 7F06-02 Module, inserted in the 7C04 or the 7C04-R Workgroup SmartSwitch, can be removed whenever necessary. Follow the steps below and refer to Figures 3-6 or 3-7 to remove the module. Note: Before removing the 7F06-02 module, attach the antistatic wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package. 1.
Chapter 3: Installation/Removal Screws FANS 4 SN 3 2 1 Ejector Tabs Figure 3-7 3-8 Removing the 7F06-02 Module from the 7C04-R Workgroup SmartSwitch 7F06-02 FDDI SmartSwitch Interface Module User’s Guide
CHAPTER 4 TROUBLESHOOTING 4.1 DIAGNOSTIC AND MONITORING SYSTEM The 7F06-02 Module uses LANVIEW, Cabletron Systems’ built-in visual diagnostic and status monitoring system. With LANVIEW LEDs the status of each transmit and receive port on the 7F06-02 Module can be determined, at a glance. This section discusses the function and purpose of the LEDs on the 7F06-02 Module. Figure 4-1 shows the LANVIEW LEDs of the 7F06-02 Module.
Chapter 4: Troubleshooting 4.2 PORT RECEIVE LEDS Table 4-1 indicates the state of the receive port. Table 4-1 Port Receive LEDs LED Color State Yellow (Flashing) Data activity (flashing to steady on indicates rate) Off No activity, port can be disabled or enabled 4.3 PORT TRANSMIT LEDS Table 4-2 indicates the state of the transmit port.
Chapter 4: Troubleshooting Table 4-3 A P S Link LEDs (Continued) B State Green Off Green Green THRU B, MAC on Secondary, Primary Bypasses Board Green Yellow Green Green THRU B, MAC on Secondary, No MAC on Primary Green Yellow Off Green THRU, No MAC on Primary, Secondary Bypasses Board Green Off Yellow Green THRU, No MAC on Secondary, Primary Bypasses Board Green Green Red Yellow WRAP A, MAC on Primary Green Yellow Red Yellow WRAP A, No MAC on Primary Yellow Green Red
Chapter 4: Troubleshooting 4-4 7F06-02 FDDI SmartSwitch Interface Module User’s Guide
CHAPTER 5 TECHNICAL SPECIFICATIONS This chapter includes the technical specifications for 7F06-02 module. Cabletron Systems reserves the right to change these specifications at any time without notice. 5.1 STANDARDS IEEE 802.1D IEEE 802.3i 10BASE-T 5.2 EMI The EMI requirements of: • FCC Part 15 Class A • EN 55022 Class A • VCCI Class I 5.3 EMC The EMC requirements of: • EN 50082-1 • IEC 801-2 ESD • IEC 801-3 Radiated susceptibility • IEC 801-4 EFT 5.
Chapter 5: Technical Specifications 5.5 SAFETY It is the responsibility of the person who sells the system to which the module will be a part to ensure that the total system meets allowed limits of conducted and radiated emissions. This equipment meets the safety requirements of: • UL 1950 • CSA C22.2 No. 950 • EN 60950 • IEC 950 5.6 SERVICE MTBF: >200,000 hours MTTR: <0.5 hour 5.7 5.7.1 PHYSICAL Dimensions 31.1D x 22.9 H x 3.1 W centimeters (12.3 D x 9.0 H x 1.2 W inches) 5.7.