- Cabletron IP Router Reference Guide
Table Of Contents
- Title Page
- Notice
- Contents
- Introduction
- TCP/IP MIB-II
- 2.1 System Group
- 2.2 Interfaces Group
- 2.3 Address Translation Group
- 2.4 IP Group
- 2.5 ICMP Group
- 2.6 TCP Group
- 2.7 UDP Group
- 2.8 EGP Group
- 2.9 OIM Subtree
- 2.10 Transmission Group
- 2.11 SNMP Management Group
- 2.12 Enterasys Interface Group
- 2.13 Enterasys Interface Port Group
- 2.14 Enterasys Com Port Configuration Group
- 2.15 SNMP Version Group
- 2.16 Trap Description
- 2.17 Enterasys MIB 2 Extensions
- Ethernet MIB
- Bridge MIB
- PPP MIB
- ELS10-26 MIB
- 6.1 System Group
- 6.1.1 Hardware Configuration Group
- 6.1.2 LXSW Configuration Group
- 6.1.3 Administration Group
- 6.1.4 Software Distribution Group
- 6.1.5 Addresses Configuration Group
- 6.1.6 Enterasys Interfaces Group
- 6.1.7 Enterasys Dot3 Group
- 6.1.8 Enterasys UART Interface Group
- 6.1.9 Enterasys Protocol Group
- 6.1.10 Enterasys Trunking Group
- 6.1.11 Enterasys Workgroup Management Group
- 6.1.12 Enterasys Trap Management Group
- 6.1.13 Ping Management MIB
- 6.1.14 Traceroute
- 6.1.15 Traceroute Management MIB
- 6.1.16 Port Mirroring
- 6.1 System Group
- Traps

TCP/IP MIB-II
2-37
ctCpAdminStatus {ctCpEntry 4}
DESCRIPTION
The administrative state of the Com Port.
SYNTAX INTEGER {disabled(1), enabled(2)}
ACCESS read-only
STATUS mandatory
OBJECT IDENTIFIER: 1.3.6.1.4.1.52.4.3.3.4.1.1.4
The OID will actually be 1.3.6.1.4.1.52.4.3.3.4.1.1.4.1 because we
only have the one UART port.
We don’t allow this port to be turned on or off. Because of this, it
will be READ-ONLY.
It will always return enabled (2).
2.15 SNMP VERSION GROUP
enableSNMPv1 Not Supported {ctSNMP 1}
This object allows control over the SNMPv1 protocol. If set to a
value of disable(1) then the SNMPv1 protocol will not be accepted
by the device.
SYNTAX INTEGER {disabled(1), enabled(2)}
ACCESS read-write
STATUS mandatory
enableSNMPv2 Not Supported {ctSNMP 2}
This allows control over the SNMPv2 protocol. If set to a value of
disable(1) then the SNMPv2 protocol will not be accepted by the
device.
SYNTAX INTEGER {disabled(1), enabled(2)}
ACCESS read-write