- Cabletron IP Router Reference Guide
Table Of Contents
- Title Page
- Notice
- Contents
- Introduction
- TCP/IP MIB-II
- 2.1 System Group
- 2.2 Interfaces Group
- 2.3 Address Translation Group
- 2.4 IP Group
- 2.5 ICMP Group
- 2.6 TCP Group
- 2.7 UDP Group
- 2.8 EGP Group
- 2.9 OIM Subtree
- 2.10 Transmission Group
- 2.11 SNMP Management Group
- 2.12 Enterasys Interface Group
- 2.13 Enterasys Interface Port Group
- 2.14 Enterasys Com Port Configuration Group
- 2.15 SNMP Version Group
- 2.16 Trap Description
- 2.17 Enterasys MIB 2 Extensions
- Ethernet MIB
- Bridge MIB
- PPP MIB
- ELS10-26 MIB
- 6.1 System Group
- 6.1.1 Hardware Configuration Group
- 6.1.2 LXSW Configuration Group
- 6.1.3 Administration Group
- 6.1.4 Software Distribution Group
- 6.1.5 Addresses Configuration Group
- 6.1.6 Enterasys Interfaces Group
- 6.1.7 Enterasys Dot3 Group
- 6.1.8 Enterasys UART Interface Group
- 6.1.9 Enterasys Protocol Group
- 6.1.10 Enterasys Trunking Group
- 6.1.11 Enterasys Workgroup Management Group
- 6.1.12 Enterasys Trap Management Group
- 6.1.13 Ping Management MIB
- 6.1.14 Traceroute
- 6.1.15 Traceroute Management MIB
- 6.1.16 Port Mirroring
- 6.1 System Group
- Traps

TCP/IP MIB-II
2-31
interface has been closed and then opened again. A read of
ctIfLAA will always return the same values as IfPhysAddress,
except in the case where; o ctIfLAA has been set, but interface has
not yet been closed and reopened, in this case the last set value is
returned. Note that a read of IfPhysAddress will always return the
physical address currently being used by the interface.
SYNTAX OCTET STRING (SIZE (6))
ACCESS read-write
STATUS mandatory
ctIfDuplex {ctIfEntry 5}
This defines the capability of the underlying hardware in
supporting full duplex. This object will have a value of
fullDuplex(3) if all hardware is capable of supporting full duplex
operation.
SYNTAX INTEGER {other(1), standard(2), full(3)}
ACCESS read-only
STATUS mandatory
OBJECT IDENTIFIER: 1.3.6.1.4.1.52.4.3.3.2.1.1.5
The OID will actually be 1.3.6.1.4.1.52.4.3.3.2.1.1.5.X where X is the
interface number requested. This is what the port is set to, NOT of
what it is capable. It will report full (3) or standard (2) on ethernet
ports, and other (1) for fast ethernet ports. It will report other (1) on
our UART (Local Console Management or PPP) port.
ctIfCapability {ctIfEntry 6}
DESCRIPTION
Defines the capability of the underlying hardware in supporting
full duplex. This object will have a value of fullDuplex (3) if all
hardware is capable of supporting full duplex operation.