DIGITAL Fast Ethernet Interface Module DELHE-UA User’s Guide
DIGITAL Fast Ethernet Interface Module DELHE-UA User’s Guide Part Number: 9032765 September 1998 This book describes the DELHE-UA features and how to install and troubleshoot the equipment. Revision/Update Information: This is a new document.
Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice.
FCC Notice — Class A Computing Device: This equipment generates, uses, and may emit radio frequency energy. The equipment has been type tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC rules, which are designed to provide reasonable protection against such radio frequency interference.
CABLETRON SYSTEMS, INC. PROGRAM LICENSE AGREEMENT IMPORTANT: Before utilizing this product, carefully read this License Agreement. This document is an agreement between you, the end user, and Cabletron Systems, Inc. (“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron software program (the “Program”) contained in this package. The Program may be contained in firmware, chips or other media.
SAFETY INFORMATION CLASS 1 LASER TRANSCEIVERS THE DELHE-UA GIGABIT ETHERNET MODULES USE CLASS 1 LASER TRANSCEIVERS. READ THE FOLLOWING SAFETY INFORMATION BEFORE INSTALLING OR OPERATING THESE ADAPTERS. The Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits. This control loop eliminates the need for maintenance checks or adjustments. The output is factory set, and does not allow any user adjustment.
DECLARATION OF CONFORMITY Application of Council Directive(s): Manufacturer’s Name: Manufacturer’s Address: European Representative Name: European Representative Address: Conformance to Directive(s)/Product Standards: Equipment Type/Environment: 89/336/EEC 73/23/EEC Cabletron Systems, Inc. 35 Industrial Way PO Box 5005 Rochester, NH 03867 Mr. J.
CONTENTS PREFACE Using This Guide .....................................................................................xi Structure of This Guide ...........................................................................xi Document Conventions .......................................................................... xii Related Documentation .......................................................................... xii Correspondence ........................................................................
Contents A.1 A.2 A.3 A.4 Physical Properties ..................................................................... A-1 Environmental Requirements...................................................... A-1 FEPIM Options............................................................................ A-1 Regulatory Compliance............................................................... A-2 APPENDIX B FEPIM SPECIFICATIONS B.1 B.2 B.3 DELTX-UI....................................................................
Figures FIGURES Figure 1-1 2-1 2-2 2-3 2-4 2-5 2-6 3-1 3-2 B-1 B-2 B-3 Page DELHE-UA ............................................................................... 1-1 Removing the FEPIM Coverplate............................................. 2-3 Installing the FEPIM ................................................................. 2-4 Removing the HSIM Coverplate............................................... 2-6 Installing the DELHE-UA ..........................................................
Tables TABLES Table 1-1 3-1 3-2 3-3 x Page FEPIM Options .........................................................................1-2 DELHE-UA LEDs ......................................................................3-2 10/100 LED Indications When RX LED Is On...........................3-3 10/100 LED Indications When RX LED Is Off...........................
PREFACE Welcome to the DIGITAL Fast Ethernet Interface Module DELHE-UA User’s Guide. This manual describes the DELHE-UA and provides information concerning features, installation, troubleshooting, information on Local Management, and specifications for the DELHE-UA. The DELVM-UA is a Fast Ethernet interface module. This manual refers to the DELHE-UA as an HSIM (High Speed Interface Module).
Preface DOCUMENT CONVENTIONS Throughout this guide, the following symbols are used to call attention to important information. Note symbol. Calls the reader’s attention to any item of information that may be of special importance. ! Caution symbol. Contains information essential to avoid damage to the equipment. Electrical Hazard Warning symbol. Warns against an action that could result in personal injury or death due to an electrical hazard.
Correspondence CORRESPONDENCE Documentation Comments If you have comments or suggestions about this manual, send them to DIGITAL Network Products: Attn.: Documentation Project Manager E-MAIL: doc_quality@lkg.mts.dec.com World Wide Web To locate product-specific information, refer to the DIGITAL Network products Home Page on the World Wide Web at the following locations: North America: http://www.networks.digital.com Europe: http://www.networks.europe.digital.com Asia Pacific: http://www.networks.
SAFETY OVERVIEW Any warning or caution that appears in this manual is defined as follows: ! WARNING Warns against an action that could result in equipment damage, personal injury, or death. VORSICHT Warnt den Benutzer vor Aktionen, die das Gerät beschädigen, Personen verletzen oder sogar zum Tot führen könnten. DANGER Déconseille à l'utilisateur d'exécuter une action pouvant entraîner des dommages matériels, corporels voire même la mort.
Safety SAFETY REQUIREMENTS The warnings or cautions that must be observed for the hardware described in this manual are listed below in English, German, French, and Spanish. WARNING Only qualified personnel should install or service this unit. VORSICHT Diese Einheit darf nur von qualifizierten Fachleuten installiert oder gewartet werden. DANGER L’installation et la maintenance de cet appareil sont réservées à un personnel qualifié.
Safety Requirements DANGER Certains FEPIM utilisent des lasers de classe 1. Ne pas utiliser d’instruments optiques pour visualiser la sortie laser, car ces instruments augmentent les risques oculaires. Pour visualiser le port optique, débrancher l'adaptateur secteur. AVISO Ciertos FEPIMs utilizan rayos láser de Clase 1. No utilice instrumentos ópticos para ver la salida láser. El uso de estos instrumentos para tal fin aumenta el peligro para la visión.
Safety ! xviii CAUTION The DELVM-UA, FEPIM, and the host module or hub are sensitive to static discharges. Use an antistatic wrist strap and observe all static precautions during this procedure. Failure to do so could result in damage to this equipment ACHTUNG Der DELVM-UA, FEPIMs und das Host-Modul bzw. der Hub sind für statische Entladungen empfindlich. Benutzen Sie deshalb ein Antistatikarmband, und beachten Sie während dieses Verfahrens alle diesbezüglichen Vorsichtsmaßnahmen.
Safety Requirements CAUTION Ensure that the FEPIM or DELVM-UA connector aligns with the DELVM-UA, module, or device connector pins to prevent bending the pins. Failure to do so can damage the DELVM-UA, FEPIM, module or device. ACHTUNG Vergewissern Sie sich, daß der FEPIM- oder DELHE-UA-Stecker gerade in den DELHE-UA, das Modul oder den Geräteanschluß eingesetzt wird und die Nadeln nicht gebogen werden. Wird er schräg eingesetzt, könnten DELHE-UA, FEPIM, das Modul oder das Gerät beschädigt werden.
Safety xx ACHTUNG Das Ende an beiden Seiten des Glasfaserkabels darf nicht berührt werden oder mit Staub, Schmutz und anderen Stoffen in Berührung kommen, die zur Verunreinigung führen und Datenübertragungsprobleme verursachen könnten. In einem solchen Fall müssen die Enden mit einem eigens dazu bestimmten Staubreiniger (z.B. einem speziellen Staubspray oder einem in Isopropylalkohol getauchten Wattestäbchen) sorgfältig gereinigt werden.
CHAPTER 1 INTRODUCTION The DELHE-UA has two Fast Ethernet ports in which Fast Ethernet (Port) Interface Modules (FEPIMs) can be installed. Figure 1-1 shows the DELHE-UA. FEPIM 1 FEPIM 2 DELHE-UA SP fepim_ports Ports 1 and 2 Figure 1-1 1.1 DELHE-UA OVERVIEW The DELHE-UA extends the functionality of certain DIGITAL interface modules by providing high-speed uplink capability through Fast Ethernet technology with different types of media. 1.1.
Chapter 1: Introduction 1.1.2 Local Management The DELHE-UA is managed through the host device in which it is installed. For information concerning Local Management for the DELHE-UA, refer to the manual for the host platform. For details on obtaining the host platform manual, refer to Related Documentation in the Preface. 1.1.3 Full Duplex Switched Ethernet The optional Fast Ethernet (Port) Interface Modules for the DELHE-UA can be configured to operate in Full Duplex Switched Ethernet mode. 1.1.
CHAPTER 2 INSTALLATION To install the DELHE-UA the following items are required: • Antistatic wrist strap • Phillips screwdriver • Fast Ethernet (Port) Interface Modules (FEPIMs) in the appropriate media Before attempting to use the DELHE-UA you should be familiar with the IEEE 802.3, 802.3 10BASE-T, and 802.3u 100BASE-T Specifications. 2.1 UNPACKING THE DELHE-UA ! The DELHE-UA and the host platform are sensitive to static discharges.
Chapter 2: Installation 4. After removing the module from its antistatic bag, visually inspect the device. If you notice any sign of damage, contact a DIGITAL representative immediately. Save the antistatic bag in the event the module must be reshipped. 2.2 INSTALLING FAST ETHERNET (PORT) INTERFACE MODULES Only qualified personnel should perform installation procedures. Fast Ethernet (Port) Interface Modules (FEPIMs) must be installed in the DELHE-UA before installing the DELHE-UA in the host device.
Installing Fast Ethernet (Port) Interface Modules Standoff Screws FEPIM Coverplate FE PIM 1 FE PIM 2 DE LH E-U A SP coverplate_remove Figure 2-1 ! Removing the FEPIM Coverplate Before installing a DELFX-UI or DELF3-UI module into the host module, remove the protective cover on the SC connector. 2. Refer to Figure 2-2. Gently pull the faceplate of the DELHE-UA forward to allow room for the FEPIM to be aligned over the connector. 3. Align the FEPIM connector into the DELHE-UA connector pins.
Chapter 2: Installation Module Module Connector Rear Standoff DEL FX-U I 10 100 DELHE-UA DELHE-UA Connector Front Standoffs feinstall Figure 2-2 Installing the FEPIM 4. Press down firmly on the FEPIM until the pins slide all the way into the DELHE-UA connector. Ensure that the FEPIM seats flush on the standoffs. 5. Secure the FEPIM using the screws enclosed in the FEPIM packaging. The screw used to attach the rear of the FEPIM to the standoff is optional and not necessary for proper installation.
Installing the DELHE-UA 2.3 INSTALLING THE DELHE-UA Only qualified personnel should install or service this unit. A DELHE-UA can be installed in any DIGITAL device that supports HSIMs (High Speed Interface Module) technology (e.g., DLE52-MA, DLE28-MA). Refer to the Release Notes for the version of firmware running on the DIGITAL host platform to ensure that the DELHE-UA is supported. The following subsections provide generic instructions for installing a DELHE-UA in an interface module.
Chapter 2: Installation 5. Remove and save the two faceplate mounting screws securing the HSIM coverplate and remove the coverplate. See Figure 2-3. DELHE-UA Coverplate Faceplate Mounting Screws 2555_03 Figure 2-3 Removing the HSIM Coverplate 6. Refer to Figure 2-4 and place the DELHE-UA behind the module faceplate.
Installing the DELHE-UA Standoff Screws Connector (top view) Connector Cutaway view of connector DELHE-UA FE PIM 1 FE PIM 2 DE LH E-U A HSIM Connector SP Standoffs Faceplate Mounting Screws Host Platform mounting Figure 2-4 Installing the DELHE-UA 7. Align the connector on the DELHE-UA with the connector on the module. ! Ensure that the DELHE-UA connector aligns with the module connector pins to prevent bending the pins. This can damage both the DELHE-UA and the module. 8.
Chapter 2: Installation 9. Secure the DELHE-UA to the module faceplate using the mounting screws saved in Step 5. 10. Secure the DELHE-UA to the module standoffs using the standoff screws included in the DELHE-UA shipping materials. 11. Reinstall the interface module in the chassis. 12. Reattach the network cabling to the interface module. 2.4 CONNECTING TO THE NETWORK The DELHE-UA can be connected to the network using either fiber optic cable or twisted pair cable.
Connecting to the Network 2.4.1 Connecting a Fiber Optic Segment to the FEPIM DIGITAL offers fiber optic cables that use SC style connectors which are keyed to ensure proper crossover of the transmit and receive fibers. An odd number of crossovers (preferably one) must be maintained between like devices so that the transmit port of one device is connected to the receive port of the other device and vice versa.
Chapter 2: Installation ! Do not touch the ends of the fiber optic strands, and do not let the ends come in contact with dust, dirt, or other contaminants. Contamination of the ends causes problems in data transmissions. If the ends become contaminated, blow the surfaces clean with a canned duster. A fiber port cleaning swab saturated with optical-grade isopropyl alcohol may also be used to clean the ends. 2. Insert one end of the SC connector into the FEPIM. 3.
Connecting to the Network Position X (crossed over) 1. RX+ 2. RX3. TX+ 4. NC 5. NC 6. TX7. NC 8. NC Position = (not crossed over) x = 10 100 DELTX-UI 1. TX+ 2. TX3. RX+ 4. NC 5. NC 6. RX7. NC 8. NC fecrossover Figure 2-5 DELTX-UI Crossover Switch A schematic of a straight-through and a crossover cable is shown in Figure 2-6. If the wires do not cross over, use the switch on the DELTX-UI to internally cross over the RJ45 port. Figure 2-5 shows how to properly set the DELTX-UI crossover switch.
Chapter 2: Installation Straight-Through Cable TO RJ45 Port TO 10BASE-T or 100BASE-TX Device Port RX+ 1 1 RX+ RX– 2 2 RX– TX+ 3 3 TX+ TX– 6 6 TX– RJ45 to RJ45 NOTE: RX+/RX– and TX+/TX– must share a common color pair. Crossover Cable TO RJ45 Port TO 10BASE-T or 100BASE-TX Device Port RX+ 1 1 RX+ RX– 2 2 RX– TX+ 3 3 TX+ TX– 6 6 TX– RJ45 to RJ45 25041-08 Figure 2-6 Twisted Pair Cabling Connect a DELTX-UI to a twisted pair segment as follows: 1.
Connecting to the Network b. Verify that the RJ45 connector on the twisted pair segment has the proper pinouts. c. Check the cable for continuity. d. Make sure that the twisted pair connection meets cable specifications outlined in Appendix B. e. Confirm that the crossover switch is in the correct position. If a link is not established, refer to Chapter 3, LANVIEW LEDs, for information before contacting a DIGITAL representative.
CHAPTER 3 LANVIEW LEDs This chapter describes how to use the LANVIEW LEDs to monitor the DELHE-UA status and diagnose DELHE-UA problems. 3.1 DELHE-UA LEDs Refer to Figure 3-1 for the location of the DELHE-UA LEDs and Table 3-1 for a description of the LED indications.
Chapter 3: Table 3-1 LED Receive Transmit 3.2 DELHE-UA LEDs Color Definition Green Link, no activity. Port enabled. Green (Blinking) Link, port disabled. Amber (Flashing) Link, activity. Port enabled. Off No link, no activity. Port enabled or disabled. Red (Solid) Diagnostic failure. Green (Flashing) Activity, port enabled. Amber (Blinking) Port in standby. Off No activity, port enabled. Red (Flashing) Collision. Red (Solid) Diagnostic failure.
DELHE-UA Local Management A link exists if the associated port RX LED is on. Table 3-2 10/100 LED Indications When RX LED Is On LED Color Indication 10/100 Off DELTX-UI is operating at 10 Mbps. Green DELTX-UI is operating at 100 Mbps. No link exists if the associated port RX LED is off. f Table 3-3 10/100 LED Indications When RX LED Is Off LED Color Indication 10/100 Off No link or no cable attached. DELTX-UI forced to 10 Mbps operation, or is manually set to “auto-negotiate” mode.
APPENDIX A DELHE-UA SPECIFICATIONS This chapter lists the specifications and regulatory requirements for the DELHE-UA. Cabletron Systems reserves the right to change these specifications at any time without notice. A.1 PHYSICAL PROPERTIES Dimensions 4.8H x 15.5W x 28.6D (cm) 1.9H x 6.1W x 11.3D (in) Weight 0.34 kg (0.75 lb) MTBF (Predicted) 200,000 hours A.
Appendix A: DELHE-UA Specifications A.4 REGULATORY COMPLIANCE This equipment meets the following safety and electromagnetic compatibility (EMC) requirements: Safety UL 1950, CSA C22.2 No.950, EN 60950, IEC 950, and 73/23/EEC Electromagnetic Compatibility (EMC) FCC Part 15, EN 55022, CSA C108.
APPENDIX B FEPIM SPECIFICATIONS This appendix provides specifications for the Fast Ethernet (Port) Interface Modules. Cabletron Systems reserves the right to change these specifications at any time without notice. The DELHE-UA supports the following Fast Ethernet (Port) Interface Modules: the DELTX-UI, the DELFX-UI, and the DELF3-UI. B.1 DELTX-UI The DELTX-UI uses an RJ45 connector supporting Category 5 (85 – 111 ohms) Unshielded Twisted Pair (UTP) and Shielded Twisted Pair (STP) cabling.
Appendix B: FEPIM Specifications B.2 DELFX-UI The DELFX-UI shown in Figure B-2 uses an SC style connector that supports multimode fiber optic cabling. Specifications for the DELFX-UI are listed in Table B-1, below. -UI DELFX 2286-40 Figure B-2 Table B-1 Cable Type DELFX-UI Transmitter Power Worst Case Budget Typical Budget 50/125 µm fiber optic 6.0 dB 9.0 dB 62.5/125 µm fiber optic 9.0 dB 12.0 dB 100/140 µm fiber optic 15.0 dB 18.
DELF3-UI B.3 DELF3-UI The DELF3-UI shown in Figure B-3 uses an SC style connector that supports single mode fiber optic cabling. Specifications for the DELF3-UI are listed in Table B-2, below. DELF3-UI 2286-68 Figure B-3 Table B-2 Cable Type DELF3-UI Transmitter Power Worst Case Budget Typical Budget 8/125 µm fiber optic >10.0 dB <10.0 dB 12.5/125 µm fiber optic >10.0 dB <10.
9032765 Printed in U.S.A.